Technical Analysis and Maintenance of CROWBAR Fault of UN5000 Excitation System;
UN5000励磁系统跨接器(CROWBAR)故障的技术分析与处理
2.
Test of short-time forward over-voltage protection with excitation crowbar in Longtan Hydropower Station
龙滩机组励磁系统跨接器短时正向过电压保护试验
3.
This paper introduces the configuration,theory and locale test method of instantaneous forward overvoltage protection to crowbar in excitation system of Longtan Hydropower Station.
本文介绍了龙滩水电站励磁系统跨接器转子短时正向过压保护结构、原理及现场试验方法,并通过试验有效验证了跨接器的动作逻辑,解决了此前现场试验手段有限,和无法判断控制逻辑正确性的问题,完善了同类型跨接器转子短时正向过压保护的试验方法。