2) Monitor and Protection
测控保护
1.
The Design of Intelligent Monitor and Protection System of AC Motor;
智能化交流电机测控保护器的设计
3) control and protection
控制与保护
1.
Design and application of PLC in the control and protection of crusher and grinder;
破碎机和磨碎机控制与保护的PLC设计与应用
2.
Control and Protection of VSC Based HVDC System under AC System Fault Conditions;
交流系统故障时VSC-HVDC系统的控制与保护策略研究
3.
For lucubrating the UHVDC technologies and the characteristics of UHV integrated AC/DC power systems,the closed-loop simulation model of ±800 kV UHVDC power transmission system was developed based on the RTDS and the world first ±800 kV control and protection equipment designed by Nari-relays Cooperation.
由于能够在任何工况下准确模拟直流输电系统行为的仿真方法只有电磁暂态仿真,所建基于RTDS的仿真模型较之机电暂态仿真模型能够提供更深刻和准确的仿真结果;由于考虑了实际UHVDC控制与保护设备的控制作用,仿真将更能反映实际交直流系统的动态特性和更具备实际工程的参考价值。
4) protection and control
保护与控制
1.
Considering the characteristics of islanding operation when DG runs out from system after failures,and combined with the protection and control status of distributed network which connected with DG,the theoretical analysis of power system and PSCAD simulation methods are used to study two islanding operation modes,i.
针对系统故障后DG与系统解列形成的孤岛运行的特点,结合DG并网运行时配电网保护与控制的现状,根据电力系统相关理论并采用PSCAD仿真方法,研究了短时间断供电及不间断供电2种孤岛运行的模式和DG形成孤岛需要满足的条件,以及不同容量的DG暂态失稳对孤岛运行的影响,提出了实现孤岛运行所要采取的与保护和控制相关的措施,据此得出短时间断供电形成的孤岛运行是目前可行的模式。
2.
The paper analyzes features of this operation scheme,introduces 2 existing islet formation modes,discusses conditions to meet form a DG islet,analyzes its impact on the original protection and control,gives out protection and control measures for islet operation.
分析了系统故障后DG与系统解列所形成的孤岛运行的特点,介绍了现有的两种形成孤岛的模式,并讨论了DG形成孤岛需要满足的条件,分析了孤岛运行时对孤岛内原有保护与控制的影响,提出了实现孤岛运行所要采取的与保护和控制相关的措施,据此得出短时间断供电形成的孤岛运行是目前可行的模式。
5) detection and protection
检测与保护
1.
One structure of parallel inverters is discussed, and the detection and protection circuits of current, voltage, temperature in this structure are designed also.
通过实验,验证了用于本并联变频器的检测与保护电路是可行的,具有较好的实用价值;设
6) measuring and protection
测量与保护
补充资料:材料保护 :电化学保护
通过改变极性或移动金属的阳极极化电位达到钝态区来抑制或降低金属结构腐蚀的材料保护技术。从伽法尼电池的两个金属电极来观察﹐腐蚀总是发生在阳极上。阴极保护就是在潮湿的土壤或含有电解质(如盐等)的水液等电解液中﹐利用牺牲阳极(如锌﹑铝等)或外加电流的惰性阳极﹐使被保护的钢铁结构成为这种人为的伽法尼电池中的阴极。在同一腐蚀环境中﹐活性较大的是阳极﹐较小的是阴极﹐例如在海水中﹐锌与低碳钢间如构成电解电池﹐锌就是阳极﹐钢就是阴极﹔但如果钢与不锈钢形成电解电池时﹐钢又变为阳极﹐不锈钢是阴极。所谓阴极﹐实际上是使电解液中的阳离子获得电子而还原的一个电极。因此﹐利用外加直流电源使它获得电子补充﹐也属於阴极保护方法。在不同的腐蚀介质中所需的保护电流密度不一。钢在土壤内﹐约为 0.0001~0.005安/分米3﹐在流动海水中约为0.0003~0.0015安/分米3﹐而在流动淡水中为0.005安/分米3 。阴极保护广泛用於保护地下管道﹑通信或电力电缆﹑闸门﹑船舶和海上平台等以及与土壤或海水等接触面积很大的工件﹐电化学保护与涂装结合则更为经济。城市和大型工厂的地下金属设备可採用这种保护方法﹐但需要注意杂散电流不致影响邻近地下金属设施的加速腐蚀。阳极保护主要用於保护钢﹑不锈钢和鈦等在浓硫酸和磷酸等强介质中的腐蚀。活性-钝性金属在阳极极化时﹐即电流导入而產生电位变化时﹐其极化曲线中有显著的活化﹑钝化和过钝化区(见图 阳极保护原理的极化曲线 )﹐对於这种情况﹐可利用稳压电源将电位控制在钝化区间﹐使腐蚀电流值降到最低限度。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条