说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 冷水供回温差
1)  temperature difference between supply and return of cooling water
冷水供回温差
1.
The technical conditions of regional cooling, including selection of refrigerating unit, distribution network form, cooling radius, temperature difference between supply and return of cooling water as well as connection modes between distribution network and end users, and application of thermal storage technology are discussed.
介绍了区域供冷技术的发展概况及优势,探讨了区域供冷的技术条件——制冷机组、输配管网形式、供冷半径、冷水供回温差的选择,输配管网与末端用户的连接方式,蓄冷技术的应用,分析了区域供冷应用中存在的问题。
2)  △T of chilled water system
供回水温差
3)  large difference between water supply and return
大温差供回水
4)  supply and return water temperature
供回水温度
1.
This paper probes into the technical measures for improving the economy of the hot water heating from two aspects of the supply and return water temperature and the specific pressure drop, and expounds the paths for improving the economy of hot water heating from the angle of operation management.
从供回水温度和比压降两方面探讨了提高热水供热经济性的技术措施,并从运行管理角度论述了提高热水供热经济性的途径。
2.
Applying the correction coefficient of heat load, the formula on supply and return water temperature in variable temperature control with varied flow is corrected.
应用热负荷修正系数,对变流量质调节供回水温度公式进行了修正。
3.
Deduces the adjustment formulas of supply and return water temperature and relative flow for both primary and secondary circuits, and gives corresponding adjustment curves with calculating examples.
推导了一、二次网侧供回水温度及相对流量的调节公式 ,并结合算例给出了相应的曲线 ,就供热参数的控制进行了讨
5)  CHCP
供/回水温度
1.
the combined heating, cooling and power (CHCP) system of Beijing is studied here, high temperature water generated by two cogeneration plants circulates through a network between the plants and heat substations.
结合北京第一热电厂、北京第二热电厂所属供热系统,分析在夏季具有冷负荷和生活热水负荷时,热网参数,即供/回水温度,对热电冷联供系统一次能耗的影响。
6)  constant difference in temperature water supply
恒温差供水
补充资料:电缆供油装置允许供油压力计算


电缆供油装置允许供油压力计算
calculation of the permissible pressure for cable oil feeding equipment

  d旧nlan gongyou zhuangZh【yunXU gongyou yol一J,suon电缆供油装t允许供油压力计算(calculationof the permissible pressure for eable 011 feedingequipment)为使充油电缆的油压保持在允许范围内,根据电缆线路的最大和最小允许工作压力,对电缆线路在环境温度最高的夏季满载时供油装t的最大允许供油压力,和在环境温度最低的冬季不带电时供油装t的最小允许供油压力的计算.最大和最小允许供油压力.取决于电缆线路的长度、高差、负荷和环境沮度等因素。 如图所示为由压力供油箱(见充油电垅供油装!)在一端供油的充油电缆线路最大和最小允许供油压力分布情况.P叮mi。P X 10一2 ~尸“m‘。十nP’r一几人沪万不万万二气陪片l一一一一一一一一一一一一_一产尸一 终端头.|一|州|||人;点叠掩__支________--一丁----------一终瑞头压力箱 卜 屯电组旦老 电缆线路由压力供油箱在一端供油时的压力分布 静态压力计算在电缆线路的负荷不变时,电缆内部的油压为静态压力。 (1)在夏季满载时压力箱的供油压力最大,线路最低处B点的油压为线路上的最大静油压,此值要小于电缆的最大允许静油压,即式中尸PT。、。为压力箱的最小允许供油压力,MP。;h、为电缆线路最高处A点的高程,m;Pcsml。为电缆的最小允许静油压,MPa,其余符号的意义同式(l). 暂态压力计算在电缆线路的负荷变化时,电缆内部的电缆油因膨胀或收缩而产生的油流在油道内分别产生暂态压力升或暂态压力降,两者均简称为暂态压力。在油压变化的暂态过程中.作用在电缆上合成的瞬时压力为暂态发生前的静态压力与暂态压力升之和。 (”电缆负荷增加时,在电缆线路的最低处B点出现最大瞬时压力不得大于电缆的最大允许瞬时油压。暂态压力升的最大值出现在冬季电缆线路由不带负荷状态突然满载时,但此时B点的静态压力最小.最大静态压力是在夏季满载时,但在夏季接近满载时产生的暂态压力升并不是最大值。因此要正确计算静态压力和暂态压力升两者之和的瞬时压力的最大值是很复杂的,但可按图所示近似地把B点的最大静态压力与最大暂态压力升之和视为最大瞬时压力,于是压力箱的最大允许供油压力应满足下列条件 尸p,二,二△尸,一尸。T,~ ‘井锣终;十h。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条