说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 交流单相瞬时故障试验
1)  single phase earth fault test
交流单相瞬时故障试验
2)  transient fault
瞬时故障
1.
The results indicate that besides holding better tolerance for transient faults,the asynchronous running based on the temporal redundancy is cost-efficient and applicable to t.
结果表明:基于时间冗余的异步运行代价较小,对瞬时故障有较强的容忍能力,符合未来处理器多线程、高可靠的发展要求;改进调度方式以消除冗余的存储访问,对RMT的性能提升至关重要;挖掘冗余线程的运行特点并结合具体硬件结构的故障特点,才能设计出高效、实用的容错机制。
2.
Hardware transient faults can cause control flow errors and corrupt the normal execution process by altering the operand and opcode of instructions.
硬件瞬时故障可以通过修改指令操作码和操作数的方式引发控制流错误,破坏程序的正常执行。
3.
Time redundancy is used to reduce faulty alarm rate for transient faults of nodes in WSNs.
对于网络中存在的节点瞬时故障,通过时间冗余的检测方法,降低故障诊断的虚警率。
3)  transient fault
瞬时性故障
1.
The study shows that in the case of solid permanent grounding, the ratio of the voltage in the fault phase shunt reactor to the voltage in the neutral point reactor is always larger than that for transient faults.
针对带并联电抗器的超高压输电线路,研究了故障后线路断开相并联电抗器与中性点小电抗上的电压特性,发现在永久性故障时,无论是金属性接地还是经过渡电阻接地,断开相并联电抗器上电压与中性点小电抗上电压的比值总是大于瞬时性故障时两者的电压比值。
2.
It can distinguish transient fault from permanent fault occurred on the EHV(Extra High Voltage) transmission line.
当瞬时性故障发生时,在短路点电弧熄灭后的恢复电压阶段,断开相各电气量的关系与永久性故障将有本质的不同。
3.
Based on extensive investigation, this paper presents a new method of distinguishing the transient faults and permanent faults on transmission lines.
提出了一种新型区分输电线路单相瞬时性故障与永久性故障的方法。
4)  permanent fault
瞬时性故障
1.
The amplitude of the voltage at the fault point of the opened phase conductor is discussed in case of temporary or permanent faults.
分析了未装设并联电抗器的超高压输电线路断开相故障点电压在瞬时性与永久性故障情况下的幅值特征及其与该点健全相电压之间的相位关系,指出瞬时性故障点电压与该点两健全相电压和同相位,而永久性故障时该点电压与该点两健全相电压和的相位差随过渡电阻及线路长度的减小而接近90度,据此提出了判断故障性质的相位判据,并针对金属性故障及线路出口处的低阻故障情况提出了补充判据,该判据可准确地判断故障性质且对于测距误差与线路参数估计误差具有良好的自适应性,大量仿真实验验证了所得结论。
2.
Main problem with the conventional reclosure scheme is a risk of a second shock to the system in the case of a permanent fault, when may lead to system oscillation.
电力系统输电线路中的短路故障大多数是瞬时性故障,因此,自动重合闸技术已经广泛应用于电力系统中,大大提高了供电的可靠性。
5)  transient faults
瞬时性故障
1.
Identification of transient faults for single-phase transmission line;
输电线路单相瞬时性故障的判别研究
2.
Taking the virtual value of three phase voltage as the input with its scale changed,the network learning can be completed with convergence reached after the process of fuzzification,normalization and perspicuity,so it can disinguish transient faults from permanent faults.
为了避免重合闸重合于永久性故障,将模糊神经网络应用于三相自适应重合闸中,构造了一个多输入的模糊神经网络,设计了网络的算法,将三相端压有效值作为输入,经尺度变换、模糊化、归一化和清晰化,并利用梯度下降法修正误差,使得网络完成学习并最终收敛,在输入故障数据时能根据网络的输出结果准确地判别瞬时性故障与永久性故障。
3.
Finally the relay can identify that the line has transient faults or permanent faults by the value of secondary arc current.
具体方法是在单相重合前,保护使用贝瑞隆模型计算线路故障点两侧的电流,进而求出故障点处的潜供电流,然后根据其有无,来区分线路是永久性故障还是瞬时性故障,从而达到避免重合于永久性故障的目的。
6)  temporary fault
瞬时性故障
1.
On the basis of detailed research a new method isproposed which can distinguish the temporary faults frompermanent faults in transmission lines.
经研究提出了一种新型的区分输电线路单相瞬时性故障与永久性故障的方法。
2.
Analysis result shows that the recovery voltage of single-phase temporary fault is superposed by free component and power frequency component, and its power spectrum possesses two spectral lines; yet the recovery voltage of single-phase permanent fault contains power frequency component only, and its power spectrum .
分析了带并联电抗器的高压输电线路发生单相接地故障时故障相恢复电压的特性,结果表明:单相瞬时性故障时的恢复电压由自由分量与工频分量叠加而成,其功率谱有2条谱线;而单相永久性故障时的恢复电压中只包含工频分量,其功率谱有1条谱线。
3.
On the basis of compare virtue and defect for existed discriminances, this paper elicited calculational expression of the open phase terminal voltage and calculated the frequency for current and voltage of the phase that is switched off with shunt compensators, and criterions to determine temporary fault and permanent fault is proposed.
本文在分析已有判别方法优缺点的基础上,通过对单相接地故障电弧熄灭后的恢复电压阶段进行较为详细的特性分析,得出了断开相端电压的计算表达式以及带并联电抗器情况下断开相端电压及线路电流所包含的频率成分,提出了判别瞬时性故障和永久性故障的新方法。
补充资料:单相交流调压电路
      对单相交流电的电压进行调节的电路。用在电热控制、交流电动机速度控制、灯光控制和交流稳压器等场合。与自耦变压器调压方法相比,交流调压电路控制方便,调节速度快,装置的重量轻、体积小,有色金属消耗也少。
  
  结构原理  交流调压电路的一般结构如图1a所示。按一定的规律控制交流开关S1的通断,即可控制输出的负载电压u0。按单相交流调压电路的控制方式有周波控制调压、相位控制调压和斩波控制调压。采用前两种控制方式的单相交流调压电路如图1b所示。图1c所示。是斩波控制的单相交流调压电路,图中的双向开关S2是续流开关。
  
  周波控制调压  适用于负载热时间常数较大的电热控制系统。控制图1b所示。中晶闸管导通时间与关断时间之比,使交流开关在某几个周波连续导通,某几个周波连续关断,如此反复循环地运行,其输出电压的波形如图2所示。改变导通的周波数和控制周期的周波数之比即可改变输出电压。为了提高输出电压的分辨率,必须增加控制周期的周波数。为了减少对周围通信设备的干扰,晶闸管在电源电压过零时开始导通。在负载容量很大时,开关的通断将引起对电网的冲击,产生由控制周期决定的分数次谐波,这些分数次谐波引起电网电压闪变。这是其缺陷。
  
  相位控制调压  利用控制触发滞后角α的方法,控制输出电压。晶闸管承受正向电压开始到触发点之间的电角度称为触发滞后角α。在有效移相范围内改变触发滞后角,即能改变输出电压。有效移相范围随负载功率因数不同而不同,电阻性负载最大,纯感性负载最小。图3是阻性负载时相控方式的交流调压电路的输出电压波形。相控交流调压电路输出电压包含较多的谐波分量,当负载是电动机时,会使电动机产生脉动转矩和附加谐波损耗。另外它还会引起电源电压畸变。为减少对电源和负载的谐波影响,可在电源侧和负载侧分别加滤波网络。
  
  斩波控制调压  使开关在一个电源周期中多次通断,将输入电压切成几个小段,用改变小段的宽度或开关通断的周期来调节输出电压。斩控调压电路输出电压的质量较高,对电源的影响也较小。图4是斩波控制的交流调压电路的输出电压波形。在斩波控制的交流调压电路中,为了在感性负载下提供续流通路,除了串联的双向开关S1外,还须与负载并联一只双向开关S2。当开关 S1导通,S2关断时,输出电压等于输入电压;开关S1关断,S2导通时,输出电压为零。控制开关导通时间与关断时间之比即能控制交流调压器的输出电压。开关 S1、S2动作的频率称斩波频率。斩波频率越高,输出电压中的谐波电压频率越高,滤波较容易。当斩波频率不是输入电源频率的整数倍时,输出电压中会产生分数次谐波。当斩波频率较低时,分数次谐波较大,对负载产生恶劣的影响。将斩波信号与电源电压锁相,可消除分数次谐波。斩波控制的交流调压电路的功率开关元件必须采用功率晶体管或其他自关断元件,所以成本较高。
  

说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条