说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 晶闸管投切电容器(TSC)
1)  thyristor switched capacitor (TSC)
晶闸管投切电容器(TSC)
2)  Thyristor Switched Capacitor(TSC)
晶闸管投切电容器TSC
1.
The Trigger Circuit for Thyristor Switched Capacitor(TSC);
晶闸管投切电容器(TSC)的触发电路
3)  Thyristor Switched Capacitance (TSC)
晶闸管投切电容(TSC)
4)  thyristor switched capacitor
晶闸管投切电容器
1.
Using a Static Var Compensator (SVC) composed of athyristor controlled reactor (TCR) and thyristor switched capacitors (TSCs) to provide dynamic var compensation isefficient to solve above problems.
由晶闸管控制电抗器(TCR)和晶闸管投切电容器(TSC)构成的静止无功补偿器(StaticVar Compensator,SVC)可以就地提供动态无功补偿,是解决这些问题的经济有效的方法。
2.
Based on the TSC ( thyristor switched capacitor ) technology,the fully adjustable parallel capacitor compensation mode has good compensational effect.
应用TSC(晶闸管投切电容器)技术的可调补偿方案具有良好补偿效果。
3.
In order to compensate more reactive power and lower the power level of the active power filter(APF),a hybrid filter system based on a combination of the APF and the thyristor switched capacitor(TSC) was presented.
为了补偿较大的无功功率,降低传统的有源电力滤波器(active power filter,APF)的容量,提出将有源电力滤波器与晶闸管投切电容器(thyristor switched capacitor,TSC)相结合构成混合滤波系统。
5)  TSC
晶闸管投切电容器
1.
<abstract>is paper presents a general introduction of TSC and then explains the four connecting models of the TSC main circuit.
介绍晶闸管投切电容器(TSC)的基本概况,阐述TSC主电路的4种接线方式,从系统变量的检测、控制目标的选取及脉冲的触发3个方面介绍TSC的控制系统,根据当前TSC还存在的一些问题,提出其应用前景。
2.
The paper introduces the technology of thyristor switched capacitor(TSC)used in the distribution systems to compensate dynamic reactive power.
介绍了用于配电系统动态无功补偿的晶闸管投切电容器(TSC)的基本原理、分类、主电路形式、控制物理量的检测、控制策略及最新的研究进展等。
3.
This paper analyzes the fault causes for incomplete phase continuity of transistor in the reactive power compensation system of TSC,and presents some c orresponding countermeasures to prevent the faults.
分析了晶闸管投切电容器(TSC)的无功补偿系统中晶闸管非全相导通故障的原因,并提出了相应的防范措施。
6)  Thyristor-Switched Capacitor
晶闸管投切电容器组
补充资料:晶闸管投切电容器


晶闸管投切电容器
thyristor switched capacitor, TSC

J ingzhaguon touq}e dI0nrongqi.用管投切电容器(thyristor switched caPac-itor,TSC)由反向并联晶闸管阀与电容器组以及小电抗器申联组成的静止无功补偿装里.晶闸管阀用于电容器的投切操作.该装t提供的容性电流只能分级调整.常与固定电抗器或晶闸管控制的电抗器、晶闸管控制的变压器、饱和电抗器配合在一起使用,以使系统能连续控制物出电流并使系统的工作范围能扩大到感性区。其主要优点是:①投切速度快;②投切操作时对系统的冲击电流小,③有功损耗小;④不产生商次谐波电流。主要缺点是:①向系统提供的无功电流只能作级差变化不能平滑调节;②正常断开后晶闸管阀所承受的电压比TCR阀要高出一倍;③有时发生谐波放大,影响正常工作。 工作原理其结构如图所示.其中限流电抗器的作用是限制电容器投人时的暂态涌流和降低主电路的电流上升率,限流电抗器的感抗值约为容抗值的百分之几.在电源电压瞬时值最大时,晶闸管阀接受来自控制器发来的触发脉冲而导通,使电容器在电流过零时开始通电,此电流半波将在电容电流再次回零时由晶闸管阀自然关断。由于TSC控制器每隔半周波便轮流向晶闸管阀两个方向的晶闷管发出整个半周波全导通的触发脉冲,所以电容器中流过的电流为连续正弦波,不含谐波分量。厂尸石「万气.丁-一十’矛‘币 TSC结构示意图 l一电容器组;2一晶闸管阅;3一限流电杭寻 性能比较晶闸管投切电容器型静止无功补偿装!与用断路器分组投切(BSC)方式的技术性能比较如下表。 用途TSC适用于主要要求补偿感性无功功率且有冲击性负荷的工业用户,用于电力系统需要快速响应,如增加系统对功率振荡阻尼、电压控制的场合。当需要较频繁地投切补偿电容器而机械投切设备又不能满足这种要求时,TSC常常成为首选。TSC也常与TCR或其它种类的补偿设备配套使用. 发展概况第一套大型TSC工业装里是1972年由瑞典原ASEA公司制造的,容量为60 Mvar,安装在瑞典的一家钢铁厂,用于电弧炉功率因数补偿,提高母线电压的稳定度,晶闸管阀的倾定电压是20kV。1980年ASEA公司又首次把TSC与TCR组配应用,用于南非ESCOM公司平衡由于单相电气化铁路负荷引起的三相电压不对称问题。中国在平顶山至武汉国内第一个500 kV输电工程中,在凤凰山变电所引进ASEA公司2套TCR+TSC型静补装置,这是世界上首例这种类型的静补装里用于500 kV输电系统。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条