1)  switching rules
开关切换规则
1.
Then, the switching rules of the PWM inverters are studied in detail.
首先在五电平逆变器数学模型的基础上对电容电压平衡规律进行分析;然后详细研究了逆变器开关切换规则与PWM控制策略,进一步提出采用目标函数最优的方法对可行开关序列寻优,实现电容电压平衡控制。
2)  on-off
“开-关”
3)  switch
开关
1.
Role of metal ionic compounds in fluorescent molecule switches;
金属离子络合物在荧光分子开关中的作用
2.
Research on driven system of switch magnetic resistance motor in mine electric locomotive;
矿用电机车开关磁阻电动机驱动系统的研究
3.
Research of model KZS-115 hydraulic reciprocating controlling switch;
KZS-115型液压往复式控制开关的研制
4)  switches
开关
1.
General-utility testing path model of switches for ATE and application;
通用ATE开关资源测试路径模型及应用
2.
The working principle and the functions of the monostability multivibrator composed of 555 timer are introduced in the paper,and the time switches are designed.
介绍了用555定时器构成的单稳态触发器的工作原理,对其功能作了进一步探讨,在此基础上设计了一种具有实用价值的定时-非定时两用开关。
3.
Three dimensional visualization is applied to low voltage switches that involve pre processing, calculation and analysis, and post processing.
从前处理、计算分析和后处理3个方面,介绍了低压开关操作机构三维可视化仿真技术。
5)  circuit breaker
开关
1.
5033 circuit breaker acting abnormally in the annual overhaul of Doushuang power line in Douli substation.
针对斗笠变电站500kV斗双线年检中5033开关动作异常情况进行了分析,找到了5033开关动作异常并导致开关保护屏中操作箱手合插件烧毁的原因,提出了应对措施。
2.
Several 500 kV circuit breaker failures and abnormal conditions since 500 kV Wanquan Substation was put into operation are listed and analyzed in this paper,and some measures to ensure safe and healthy operation of equipment is also proposed in view of equipment selection,installation& commissioning,acceptance,operation and maintenance.
列举了5 0 0 k V万全变电站自投运以来所发生的几起5 0 0 k V开关事故及异常,对事故及异常发生的原因进行了分析,并从设备的选型、安装调试、验收、运行、检修等方面提出了确保设备安全健康运行的措施。
3.
In this paper,the authors analyzes the main reason of the insulated pin fault,propose some suggestions and the key overhaul item about type LW6-220 circuit breakers.
通过对一起绝缘拉杆脱落故障的主要原因分析,提出了针对LW6型开关的重点检修改造项目,对防止高压开关发生非全相故障,保证电网的安全稳定运行具有积极的意义。
6)  breaker
开关
1.
Causes analysis about one point earthing leading to breaker tripping in DC system;
直流系统负极一点接地致开关跳闸原因分析
2.
Problems existing in malfunction protection during operation were analyzed,there are two problems in it,one is that one-phase re-switching might not work when the outlet breaker of malfunction protection instantaneous trip circuit is sprung,the other is that malfunction might be caused when malfunction protection outlet connects to TJP of phase separated box.
失灵保护存在两个问题:一是失灵保护瞬跳线路出口开关可能造成单相重合闸拒动;二是失灵保护出口接分相操作箱的永跳端子TJR时,可能造成误动。
3.
Pole-mounted SF6 breaker product is an electical apparatus widely applied in power supply and distribution net-works.
柱上SF_6开关产品是广泛应用于供配电网的电器。
参考词条
补充资料:备用电源自动切换装置


备用电源自动切换装置
automatic transfer to stand-by supply

be(yongd旧nyt一anz一dongq旧hoon zhuongzhl备用电派自动切换装t(automati。transferto stand一by supply)当工作电源消失或当工作电压降低过多时.能将备用电源断路器快速合闸向负载恢复供电的自动切换装置。 自动切换的一次系统常用的设自动切换装置的一次系统接线有以下两种:①两个电源(两台变压器或两条线路)互为备用。正常运行时,两个电源分别工作,电源之间设有经常断开的自动切换断路器,当其中一个电源故障时,另一个电源通过切换断路器迅速投人而恢复运行。这种自动切换方式通常称为暗备用。两个电源需具有充分的容量,以便在故障情况下由同一个电源向两个负荷供电。②利用一个备用电源作多个工作电源的备用.当一个工作电源故障退出运行时,备用电源自动投人,这种方式通常称为明备用。 自动切换装里功能切换装置的接线具有以下基本功能:①当工作电源消失时,快速起动自动切换装里,投人备用电源;②当工作电源母线电压降低,由接在母线上的低电压继电器动作,进行切换;③备用电源自动投人装置只能动作一次;④工作电源母线故障时,备用电源不允许投人。 火力发电厂备用电源自动切换接线,常用的有慢速切换和快速切换两种方式。 慢速切换为工作电源断路器断开后,经延时,当电动机残压下降到电动机允许的安全电压后才实现自动切换。当工作电源侧断路器跳闸时,联动受电侧断路器跳闸,以起动备用电源自动投人装置。同时,在工作母线上装设单独的低电压起动装置,当工作电源电压降到安全值,即20%~30%额定电压以下,而备用电源母线上保持一定电压值时,使备用电源断路器合闸。慢速切换时间一般为0.5一1·5s。 快速切换装置主要用于300 MW及以上容量的发电机,这种切换方式对电动机的冲击及对机组热力系统的正常运行影响较小,切换过程平衡。实现快速切换的条件是工作和备用电源断路器必须快速动作,要求合闸及跳闸时间为0.06~0.085。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。