说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 工频交流耐压
1)  withstanding of power frequency AC electrical equipment
工频交流耐压
2)  industrial frequency withstand voltage
工频耐压
1.
During trial manufacturing period of model KYN □ -12 built-in cabinet, the industrial frequency withstand voltage test of cabinet to earth can not be passed, the problem was found out with insufficient out isolation strength of the fuse base, finding out that there are a lot of air holes on the sectional surface of the parts broken through.
KYN□-12型中置柜在试制阶段,柜体相对地的工频耐压试验通不过,问题出在熔管座的绝缘强度不够,发现被击穿零件部位的断面存在大量的气孔。
3)  AC high voltage power
工频交流高压
4)  AC withstand voltage
交流耐压
1.
some experience and methods of AC withstand voltage test on220kV XLPE cables were presented in this paper,the method of resonance in series with compensation in parallel may help to test on HV cables with ex tra-length in the future.
介绍了220kVXLPE电缆现场交流耐压试验的一些经验和方法,特别是采用串联谐振并联补偿的方法为今后高电压等级超长度的电缆试验提供参考。
2.
This paper summarized global research status of test equipment of UHV transformer’s AC withstand voltage and partial discharge tests.
综述了国内外特高压电力变压器交流耐压和局部放电试验装置的现状;以武汉高压研究院特高压试验基地1 000 kV变压器的试验数据为参考,提出了特高压电力变压器的交流耐压和局部放电的试验方法和试验电路。
5)  AC voltage withstand
交流耐压
1.
An AC voltage withstand test on XPLE cable was carried out by using series resonance method in order to improve the limitation of DC voltage withstand test.
针对直流耐压试验方法的局限性,介绍应用超低频耐压试验、串联谐振及变频谐振方式来进行交联聚乙烯电缆交流耐压试验,结合现场试验的经验介绍其试验原理和电气参数的计算方法。
2.
1Hz) ultra-low frequency AC voltage withstand tests on XPLE cable in order to alleviate the damage to cable insulation.
1Hz超低频交流耐压试验方法在交联电缆(XPLE)预防性试验中的应用与日常使用的几种试验方法进行分析对比,从中减轻试验对电缆绝缘的破坏作用。
6)  AC withstand voltage test
交流耐压
1.
This paper discusses mainly its structural characteristics,field installation method and process especially its installation in vertical shaft as well as field AC withstand voltage test,and the difference with GIS,which can be used for reference in the equipment selection and installation of other similar projects.
为此,就其结构特点、现场安装方法及工艺,特别是在垂直竖井中的安装方法以及现场交流耐压试验与GIS的差异进行了重点论述,以供同类工程的设备选型及安装参考。
2.
It also reflects a great inconvenience and risk to the power system during the AC withstand voltage test for 220 kV GIS.
GIS设备以其性能优良、免维护等优点给电网安全稳定运行带来了保障,同时也带来了扩建或处理缺陷时的困难,停电及交流耐压也给系统带来了较大风险。
补充资料:交流电动机频敏变阻器起动


交流电动机频敏变阻器起动
starting of AC motor by frequency-sensitive rheostat

  加而增大。rll︷卜 fb .。 ┌──┐ │}· │ ├──┤ │卜1 │ ├──┤ │卜..│ ├──┼───┐ │L │愁一 │ │滩 │!城.味│ └──┴───┘┌───────┐│.-.一’, │└───────┘ 图1孩敏变阻器 (a)结构示意图;(b)等效电路 频敏变阻器起动的接线图如图2所示。起动初始阶段,由于转子电流频率较高,颇敏变阻器的阻抗(主要是铁耗等效电阻)较大,因而限制了起动电流,同时也增大了起动转矩.随着转子转速的升高,转子电流频率逐渐降低,频敬变阻器铁耗的等效电阻rm也随之减小,这就相当于在起动过程中逐渐减少转子回路的电阻.起动过程结束后,转子电流频率很低(l~3H:),颇敏变阻器的阻抗很小,此时可将它切除,并把转子绕组直接短路。人日C领徽变阻器┌──┐│1从 │└──┘ 图2频敏变阻器起动接线图 设计频敏变阻器时,适当地选择反映铁芯损耗的等效电阻和铁芯线圈的电抗值,就可以得到较大的、近于恒起动转矩的机械特性。对于容量较大的电动机,还可由多台频敏变阻器作申、并联组合使用.在选用频敏变阻器时,应注意有不经常起动等轻载型、重轻载型、重载型及断续起动的不同类型并加以区别.J一001旧d旧ndongl一Plnm旧blanzuq一q一dong交流电动机频敏变阻器起动(s tarting of ACmotor by frequeney一sensitive rheostat)在烧线转子感应电动机转子回路申人频敏变阻器进行起动的方法。频敏变阻器起动是一种无触点变阻器起动,它能自动、无级地减小电阻,避免了转子串电阻逐级切除时的电流冲击和转矩冲击,而且大大简化了控制系统。频敏变阻器起动结构简单,运行可靠,使用和维护方便,因此应用日益广泛。但与交流电动机转子串电阻起动相比,由于频敏变阻器具有一定的电抗,在同样起动电流下,起动转矩要小些。 频敏变阻器是一个三相铁芯线圈,它的铁芯用厚30一50mm的几片或十几片钢板亚成,三个铁芯柱上绕有匝数较少的三相绕组,并接成星形,其结构和等效电路如图1所示。等效电路图中的x为一相绕组的电抗;r为一相绕组的电阻,由于匝数少,r的数值不大;r。是反映铁芯损耗的等效电阻,由于涡流损耗与频率的平方成正比,因此铁耗等效电阻、的值随频率的增
  