1)  closing [英]['kləʊzɪŋ]  [美]['klozɪŋ]
合闸
1.
An analysis of opening and closing switch for GW4 disconnector;
关于GW4型隔离开关一个典型分合闸问题的分析探讨
2.
The control circuit of Unit 1 generator circuit breaker in Yunfu Power Plant hit a peculiar kind of fault;the automatic quasisynchronization closing failed sometimes and intense arc took place on the contacts of some relays during the failure.
云浮发电厂1号发电机出口开关控制回路出现一种特殊的故障现象,自动准同期合闸有时失败且合闸失败时在某些继电器接点上产生强烈的电弧。
3.
It also demonstrates that when closing and reclosing overvoltages are only limited by different type MO As, terminal switching overvoltage of each line is be.
计算了铁岭500kV系统中5条线路在不同年代、不同接线、不同运行方式下的工频过电压、潜供电流以及仅用不同型号MOA限制这些线路的合闸及重合闸(单重)过电压。
2)  switch on
合闸
1.
For the retrofitting substations,the remote switch on operation with synchronism check can not be carried out because of the equipment limitation.
对于旧站改造的“四遥”变电站 ,由于设备的限制 ,同期合闸无法实现遥控操作。
3)  Switch-on [英]['switʃɔn]  [美]['swɪtʃɑn]
合闸
1.
Improvement of the Switch-on Loop of the 6kV Motor;
6kV电动机合闸回路的改进
2.
The regressive analysis is introduced to estimate the switch- on time in the power station of the ship in this paper,which overcomes the faults of the pbase difference method and increases the switch-on accuracy.
采用回归分析法估算船舶电站的合闸时间,从而克服了相位差法的缺点,提高了合闸的准确性。
4)  close [英][kləʊs]  [美][klos]
合闸
1.
Application of isolation transformer in synchronous voltage loop of non-synchronous close in double-side circuit breaker of transformer;
隔离变压器在变压器双侧断路器非同期闭锁合闸同期电压回路中的应用
2.
Analysis of Circuit Breaker Re-close After This Breaker is Opened;
关于一起断路器分闸后自动合闸的分析
5)  switching on
合闸
1.
Over voltage analysis for switching on unloaded transmitting lines in processing of black start system restoration in Fujian power grid;
福建电网黑启动恢复过程中空载合闸过电压分析
2.
Simulation of Transient Process in Switching on Transformer when No-Loaded and its Application in Computer Test System;
变压器空载合闸瞬态过程的仿真及其在计算机测试系统中的应用
6)  trip-reclosure
跳闸-重合闸
1.
The proper setting of the trip-reclosure time on a transmission line is substantial in improving power system stability.
本文以跳闸-重合闸电气操作全过程为研究对象,建立了跳闸-重合闸操作时机对电力系统稳定性影响的数学模型,并使用能量函数导出了最佳操作时机的条件及其整定策略。
补充资料:电力系统合闸过电压


电力系统合闸过电压
energization overvolt-age in electric power system

  dianllx{tong触Zha guodlonyo电力系统合阐过电压(energization Over-voltage in electrie卯wer system)主要是指断路器合闸空载线路导致瞬态振荡所引起的过渡过程过电压。是决定330kV及以上的超高压电力系统操作冲击绝缘水平的主要依据。合闸过电压与合闸前线路上残留电压的大小、极性以及合闸时电派的相角有关。因为这些t均为随机变量,所以合闸过电压具有明显的随机性.若合闸前线路上有较高的残留电压,又恰好合闸于极性与线路残留电压相反的电源电压时,合闸过电压最大。三相重合闸过电压(尤其是不成功的三相重合闸过电压)要比单相重合闸或无故障正常合闸过电压高。合闸过电压还与系统容t、线路长度及结构有关,电源容盘小、线路长,合闸后的工频过电压商.合闸过电压更高;空载长线路沿线各点的合闸过电压幅值不等,对于无高压并联电抗器和进雷器的线路,最大过电压出现在线路的开路端,线路两端装有进苗器或高压并联电抗器时,最大过电压出现在线路的中部。 限制合闸过电压的主要措施有高压并联电扰器、进雷器和断路器并联合闸电阻,这些措施应综合考虑。高压并联电抗器主要是限制工频过电压。金属氧化物避雷器可以释放过电压的能t,将过电压限制到一定的水平,但它有一定的保护距离,靠近避雷器处的过电压可以限制得较低,随着离进雷器处的距离增大,限制效果逐渐减小。断路器并联数百欧姆的合闸电阻,可以将全线路的合闸过电压限制到较低的水平,但断路器加装合闸电阻使操作机构复杂,不仅使造价增大,而且使运行可靠性降低。对于超高压和特高压的长线路,首先应采用线路安装高压并联电抗器限制工预过电压,然后应用线路安装金属饭化物避雷器将合闸过电压限制到允许的水平,如以上措施还不能满足要求,再增加断路器加装合闸电阻的措施。 正在研制断路器受控合闸装t,即控制断路器在两端电位差为零或接近零时完成合闸,以使合闸过波过程降低至最弱程度,这对特高压交流摘电是必要的。该装置已在加章大运行,其长期使用可靠性还裕进一步在运行中检验。
  