1) AC/DC system
交直流系统
1.
Voltage weak stability zone calculation of AC/DC system using eigenvalue method;
运用特征值法确定交直流系统电压失稳区
2.
By scanning the AC/DC system in low frequency band,the frequency domain characteristics of controller were derived,which should satisfy the desired performance and stabilize the system.
通过对交直流系统进行低频范围内的频率扫描,可以得到满足系统稳定性要求的控制器频域特性,并以此为约束条件确定控制器的结构和参数。
3.
Based on the reliability model of a bipolar HVDC system, one DC line is equivalent to two AC lines, so that an AC/DC system can be transformed to an equivalent pure AC system, and the failure of DC systems with monopolar total outage or bipolar total outage can be analyzed with the equivalent of being failure AC lines, and evaluated with suitable AC transmission reliability assessment software.
基于双极直流系统的可靠性模型,用两条交流线路来等效一条直流线路,将交直流系统等效为纯交流系统,利用交流线路的故障来模拟直流系统的单极停运和双极停运,然后可基于适合于交流输电网可靠性评估的软件来对交直流系统进行可靠性评估。
2) AC/DC power system
交直流系统
1.
A new segment solution for solving load margin of AC/DC power system is proposed in this paper based on continuation method and interior point algorithm.
基于连续潮流法和原始-对偶内点法,提出了一种新的分段求解交直流系统负荷裕度方法。
2.
In load flow calculation of AC/DC power system the adjustment of converter transformer’s tap changer is taken into account, the mathematical model and method to adjust the position of taps are proposed and their simulation results for two-terminal and three-terminal HVDC transmission systems are given.
分析了直流输电系统中换流变压器的作用,在交直流系统潮流计算中考虑了换流变压器分接头的调整,提出了调整分接头档位的方法,并通过两个算例系统进行了仿真。
3.
The assumption of the AC commutating voltages being unchanged during the fast HVDC simulation can affect the results of the two-time-step transient stability simulation of the AC/DC power system.
分析在直流小步长仿真过程中假设换流母线的交流电压不变对交直流系统双时步暂态稳定性仿真结果产生的影响及原因:该假设可能会延迟直流系统中一些具有开关特性的控制器的动作时间,造成仿真结果不准确;对于多馈入直流系统甚至可能引起直流开关特性控制的误动作,从而使仿真结果失真。
4) AC/DC power systems
交直流系统
1.
Considering the variable constraints of DC system,the adjustment of operation mode and convergence during assessing the voltage stability of AC/DC power systems,this paper proposes a new segment method for solving load margin of AC/DC power system based on the primal-dual interior point algorithm.
针对交直流系统稳定分析时直流变量约束、运行方式调整以及计算收敛性问题,基于原始-对偶内点法提出分段求解交直流系统负荷裕度的新算法。
5) AC-DC power system
交直流系统
1.
The dynamic characteristics of the AC-DC power system can be reflected accurately by electicmaganetic simulation tooles with the external actual DC control and protection devices.
利用实时电磁暂态仿真工具可以与实际直流输电控制设备连接,精确模拟交直流系统的动态特性。
6) low SCR systems
弱交流/直流系统
补充资料:交直流转换
交直流转换
AC-DC transfer
交直流转换有热电变换、电动系、静电系、电子系等方法。迄今,热电变换仍是一种误差小、灵敏度高、有较好稳定性的交直流转换方法。热电变换器由加热丝和热电偶组成,其间有云母绝缘,原理如图所不。┌─┬──────┬───┐│ │1 1 .1 │/ ││ ├──────┤声尸 ││ │’缨:::::缈 │ 沪碑│└─┴──────┴───┘ 热电变换器原理示意图 1.加热丝;2.云母片;3.热偶洪.隔离云母片; 5.冷端散热片;6.加热丝引线刃.热偶引线 电流通过加热丝所产生的热量使热电偶产生热电势,大小决定于通过加热丝的电流。有效值相等的交流和直流电流在加热丝上产生的电功率相等,翰出的热电势也相等,由此可实现交直流电流的比较。 热电变换器的交直流转换误差中包含有在热电转换过程中通过直流和交流电流时,由于一些物理效应(汤姆孙效应和帕尔蒂效应)的影响不同所引起的直流误差,这是因为,这些效应所引起的附加发热在通过直流时不能像通过交流时可以抵消。此外,还有高频下容性泄漏和趋肤效应所引起的高频误差,以及低频下温度波动所引起的低频误差。单元热电变换器的转换误差小于1 x 10一5,使用频率可到10MHZ;多元热电变换器的转换误差则小于1 x 10’‘,但其频率特性较单元热点变换器的差,一般只使用在lookHZ以下。中国研制的具有保护热电偶的多元热电变换器在4OHZ-15kHZ范围内交直流转换误差小于1 x 10一‘。还有一种称为薄膜型的热电变换器,是利用集成电路制造技术将加热丝和热偶都集中在一块小基片上而成的,目前有的已做到2(X)多个结。其频率特性介于单结和多结变换器之间,可使用到1 MHz以上,在100翻Hz以下不确定度也可达10一6数t级。 近年来发展起来的模数转换器和采样及数据处理技术,也可看作为一种交直流转换方法,尽管准确度目前还比不上热电转换,但已经取得了很多实际应用。当模数转换器对交流信号采样测量时,得到的是交流信号的瞬时值,再按照交流量的定义,通过计算获得如有效值、平均值等特征量。由于模数转换器一般是以直流参考电压(齐纳管)为转换标准的,因此实际上这也是一种交直流转换。为了提高转换精度,人们在提高数模转换器的性能(速率和位数)、改进采样策略和数据处理方法等方面进行了有意义的工作。目前这种┌───┬───────────────────────────────┐│计 │鑫 ┌───────┐ ││t │ │}电。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。