说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 连锁故障
1)  cascading failure
连锁故障
1.
Dynamic modeling and analysis on cascading failure of complex power grids;
复杂电力网络的连锁故障动态模型与分析
2.
Risk assessment of cascading failure in power system based on fuzzy neural network;
基于模糊神经网络的电力系统连锁故障风险评估
3.
Review of cascading failures in electric power network;
电力网络连锁故障研究综述
2)  cascading failures
连锁故障
1.
According to complex system theory, power systems in self-organized criticality (SOC) state have high probability of occurring of cascading failures.
根据复杂系统理论,电力系统在自组织临界状态下发生连锁故障的概率将会大大提高。
2.
With the development of complex network theory,especially the discovery of small-world characteristics in the power grid,increasingly great concern is shown about the relationship between the complex structural characteristic and the cascading failures of power grid.
文中以复杂网络科学理论为基础,考察了小世界电网中节点的非均质特性,提出多种故障模式和故障指标,重点分析了连锁故障在小世界电网中传播的内在机理,并提出改善小世界电网承受故障能力的有效措施。
3.
For the sake of determining the impact of small-world property on probability of occurring cascading failures in power systems, the cascading failures are simulated in several power systems among which some have small-world property and the others have stochastic network property.
为了得出小世界网络特性对电网发生连锁故障的影响,文中对几个具有小世界特征的电网和几个具有随机网络特征的电网进行了仿真分析,结果发现无论是具有小世界网络特征的电网还是具有随机网络特征的电网,在一定的条件下都表现出自组织临界性,即发生连锁故障的“故障规模—故障概率”分布曲线呈现出幂律特征。
3)  cascading outage
连锁故障
1.
It is greatly relevant to serious failures,particular to the cascading outages.
输电线路过负荷或故障跳闸,将引起大量负荷转移,进一步造成一系列线路和电源的连锁跳闸,它与重大停电事故尤其是连锁故障的发生具有强相关性。
2.
Forecasting and preventing strategy for cascading outages is primarily discussed in this paper according to the rule of successive breaks in cascading outage process of power grid.
本文就电网连锁故障的防治问题以相继开断为原则分别对相继开断预想事件的预测策略以及防治策略进行了初步探讨。
3.
Many severe cases of black outs have taken place recently among different countries, most of which exhibit cascading outage, so the study on cascading outage of power grid is becoming more and more popular.
由于近年来世界范围内发生了不少大停电事故,这些事故多表现为连锁故障,因而电网连锁故障的研究日益受到重视。
4)  cascaded outages
连锁性故障
1.
They consist of needs for further stability mechanism research, causes and control strategies of cascaded outages, a systematical method for the research of power systems collapse prevention, improvement on adaptation of control strategies and its combination with optimization methods, requirements for DC supply to AC system unde.
分析了电力系统灾变防治研究中有待解决的一些问题,如稳定现象的机理、连锁性故障发生的原因及其控制策略、电力系统灾变防治的系统化研究方法、直流输电系统对交流输电系统的紧急支援、电力系统的动态安全监视和实时信息利用、基于局部信息的暂态稳定控制以及系统重要部件(或环节)控制系统的可靠性和容错控制研究等,并针对上述问题提出了一些研究建议。
2.
Several special considerations in the research of power system collapse prevention system are presented,such as cascaded outages,control mode and strategy concerning rare severe faults, needs for a power system prediction and protection system,a systematical method for the detection of power systems weak parts,and so on.
文中分析了电力系统灾变防治问题的难点和电力系统灾变防治系统研究中的特殊问题 ,对电力系统动态安全分析、稳定控制、恢复控制、电力系统隐患的探测和预防以及连锁性故障发生的机理和控制策略等方面的研究现状及存在问题进行了简要概述 ,并指出了该系统最终应达到的目标和实现的可能性。
5)  cascading failure
连锁反应故障
1.
The cascading failure is an important cause leading to large-scale blackout of power grid.
连锁反应故障是导致大停电的重要原因。
6)  Power system chained failure
电网连锁故障
补充资料:DCS—50型电子定量包装秤常见故障检修
DCS—50型电子定量包装秤计量准确度高,稳定性好,包装速度快,广泛应用于制糖及化工行业。现把该秤常见故障的检修介绍如下:

  一、部件组成

  该秤主要由电气和气动两部分组成。电气部分采用MCS—51单片机系统和XK3113数字显示件相结合,以P8031为中心,该系统的故障率很低;气动部分由加料主气缸、放料气缸、夹袋气缸和电气换向阀组成,由于连续运行,其故障率占到80%左右。

  二、常见故障检修

  1夹袋机构不动作。说明电气转换阀没有正常工作,在气源气压正常情况下,首先检查换向阀线圈电压(24伏)是否能被控制,若电气转换正常则为换向阀故障,应更换,如果不能切换,对应的检修流程为夹袋开关、换向阀控制三极管、双向触发器(CD4013)光电耦合器。

  2重量显示不稳定,时好时坏。首先应该排除秤体震动现象,检查+5V系统供电电压是否稳定,秤体接地电阻是否符合要求。

  3料斗漏糖。料斗漏糖与放料机构故障有直接关系,清除斗内积糖,观察放料气缸是否到位,关门阀是否有积糖。如以上均正常,则应检查放料气缸密封性是否良好。在此气缸下部有一阻尼调整螺丝,当调整螺钉气孔堵塞时,会出现关门延时,而出现漏糖。疏通气孔后,最佳的调整方法是:及时关门,响应时间要短,又要保证具有良好的阻尼,否则,关门机构过量冲击料斗,造成数字显示不稳定,且机械手磨损快。

  4下料重量不稳,超差现象严重。该秤三联件中有一储油杯,气源通过油杯,带动润滑油进入各气缸及换向阀,主要作用一是润滑缸体,二是加强密封性能。当油路堵塞时,会造成气缸密封橡胶垫圈与缸体干磨,而出现破损,造成串气,影响气缸各级加料行程,通过更换主气缸两级橡胶垫圈,一般都能奏效,但同时应疏通油路。另外,该三联件上还设有一油量调整螺钉,如调整过大,也会造成润滑油直接外排而浪费;过小则起不到作用。具体调整应为每7天左右一杯油。

  5放料过程中缺少某一级加料过程。下料过程中缺少某级加料过程时,应仔细观察主气缸的到位情况,Q1,Q2,Q3,电气换向阀分别控制气源至主气缸电位的高低,应根据故障现象检查其对应的换向阀,Q1,Q2,Q3,分别负责一、二、三级加料过程气源的供给。在更换换向阀时,应将它的两种工作状态旋至“0”位。在排除了换向阀的原因后,进一部检查信号接口电路,各自的信号由光电耦合器输出至控制三极管,参数为BV>60V,Zcm>3A,Pcm>40W的达林顿管。

  6不能启动自动程序。首先检查放料气缸是否关闭,在气缸关闭的情况下,位置传感器是否松动、到位。位置传感器实际上就是一干簧开关,靠气缸内环形永磁体来实现关与开。当传感器位置不正确,气缸内永磁体磁性减弱都会引起信号失控,而出现自动程序不启动。在调整传感器位置无效时,可做应急处理:将传感器输出线短接,实际并不影响使用。

说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条