说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 密闭爆发器试验
1)  closed bomb test
密闭爆发器试验
1.
With the measuring technique for the density of propellant grain and closed bomb test,the damage level of the samples was analyzed and the combustion characteristics of the damaged propellant charge was studied.
采用药柱密度测量技术和密闭爆发器试验,分析了试样的损伤程度,并对损伤装药的燃烧性能进行了研究。
2.
The effects of physical dimension(inner diameter and length-to-diameter ratio) on the combustion performance of a tubular variable-burning-rate gun propellant were investigated by closed bomb test.
利用密闭爆发器试验,研究了管状变燃速发射药的几何尺寸对燃烧性能的影响,将实验与理论Γ-Ψ曲线进行对比。
2)  closed bomb test
密闭爆发器实验
1.
And Differential Thermal Analysis method and closed bomb test were used to research the variety of the combustion property.
密闭爆发器实验以太根药为研究对象,对催化剂引起燃烧性能的变化情况进行了初步研究。
2.
The sheet multilayer charge with different content of deterrent material and different layer constructions was investigated by closed bomb test and 30 mm simulation gun shootong.
对不同阻燃剂含量和不同厚度比的片状多层发射药进行了密闭爆发器实验和30mm模拟弹道炮试验。
3)  manometric bomb
密闭爆发器
1.
The poisonous gas in combustion gases for gun propellant by manometric bomb test was analyzed by infrared spectrum technique.
采用密闭爆发器模拟发射药实际燃烧过程中生成燃气,并用红外光谱分析技术检测发射药燃气成分中毒性气体。
2.
The combustion process in oil well in high-energy gas fracture is simulated by manometric bomb test.
利用密闭爆发器测试技术模拟了高能气体压裂弹的爆燃过程,并使用红外光谱分析技术对燃气成份中毒性气体进行了检测。
3.
The combustion process of high energy gas fracture in oil well is simulated with manometric bomb,the poisonous gas produced in the process is analyzed by infrared spectrum technique.
用密闭爆发器模拟高能气体压裂弹在油井中的燃烧过程,用红外光谱分析技术检测燃气成份中的毒性气体,测试了7个不同生产厂的高能气体压裂弹产品的燃气成份,并对特殊产品燃气中产生HCN机理进行了分析。
4)  Closed bomb
密闭爆发器
1.
A modified closed bomb was used to study burning rate characteristic of propellant enhanced by plasma.
利用改进的密闭爆发器对等离子体增强火药燃速的特性进行了实验研究。
2.
Some catalysts are putting into TEGDN gun propellants and the effect of these catalysts on combustion properties of TEGDN gun propellant is studied through closed bomb test.
将燃烧催化剂引入太根发射药中,利用密闭爆发器静态燃烧实验研究了这些燃烧催化剂对太根发射药燃烧性能的作用效果。
3.
Two factors resulting in pressure loss in closed bomb test were discussed.
分析了造成密闭爆发器实验时压力损失的两个因素,从造成压力曲线损失的理论关系式出发,无须测量密闭爆发器的壁温曲线,仅根据压力曲线得到了一种适用于火药燃烧的全过程的压力修正方法。
5)  closed bomb test
密闭爆发器
1.
The combustion properties of TEGDN propellant were evalucated by closed bomb tests.
本文以探讨火药配方组成与燃烧性能的关系为研究目的,通过密闭爆发器实验,研究了加入不同含量的RDX对太根发射药燃烧性能的影响,并在含RDX的太根药(改性太根发射药)里再加入Pb_3O_4,研究改性太根发射药在加入Pb_3O_4后的燃烧性能的变化。
2.
The experiment was mainly on the research of the closed bomb test.
试验中选择了五种不同类型的燃烧催化剂,对含有催化剂的火药进行了准备,并借助密闭爆发器定容燃烧试验手段,开展了含有催化剂发射药的燃烧性能试验研究。
3.
First,the closed bomb test is used to reaserch NG that appends different catalyzers.
首先对含催化剂的双基药进行密闭爆发器定容燃烧试验研究,由实验得到的压力时间曲线,经过密闭爆发器实验数据处理程序处理,最终得到了不同压力段的压力指数,压力指数的变化情况能说明催化剂对燃烧所起催化作用的大小,通过与不含催化剂的双基药的压力指数对比研究,发现了几种较好的催化剂。
6)  confined gap test
密闭殉爆试验
补充资料:变压器试验
      为保证变压器安全、正常运行,对变压器所进行的各类工业试验。包括半成品试验和成品试验。前者包括部件试验和工序试验;后者包括出厂试验、型式试验等。试验项目有电压比试验、绝缘特性试验、空载试验等十多项,具体试验项目与程序见下页表1。
  
  电压比试验  一般用双电压表测定法。低压侧开路,在高压侧加一低电压(小于250伏),同时读出原、副边电压U1和U20,即可得电压比K为
  
  
  
  
  K=U1/U20
  式中U1为原边(高压侧)电压,U20为副边(低压侧)电压。除双电压表法外,还有变比电桥法。它的准确度和灵敏度都较高,但需用专用的变比电桥。
  
  空载试验  测量变压器的空载电流和空载损耗,以判断铁心质量和检查绕组是否有短路。试验时,在低压绕组上施加额定频率正弦波形的额定电压,其他绕组开路。测量所有三相的电流、电压和功率。这时变压器所消耗的功率称为空载损耗,主要是铁耗。铁心的磁通密度过高会使空载电流增加;硅钢片绝缘不良、片间短路、绕组匝间短路及穿心螺杆绝缘损坏等因素都会使空载电流增大、损耗增加。
  
  短路试验  测量变压器的短路损耗和漏阻抗电压。试验时,将变压器低压绕组短接,在高压侧施加额定频率的较小正弦电压,使绕组中的短路电流等于高压绕组的额定值。此时所加试验电压为短路电压,又称漏阻抗电压。短路试验中测得的损耗为短路损耗,即变压器额定运行时绕组的电阻损耗,又称铜耗。
  
  生产厂家检验产品质量,使用部门进行变压器大修更换绕组,进行事故检查,以及新变压器验收时,都要进行短路试验和空载试验。
  
  绕组极性测定  常用交流感应法,其接线见图1。将变压器低压侧的u端与高压侧的V端用导线连接。在高压侧加一较低的交流电压(小于250伏),测出电压表的指示值。如果V=V1-V2,则为减极性,表示V与u是同极性端;反之,则为加极性,表示V与u端的极性相反。
  
  
  绕组联接组标号的测定  其试验接线见图2。将高压侧的A端与低压侧的a端用导线连接。在高压侧加一较低的三相交流电压(一般小于250伏),用电压表依次测量其他几个线端之间的电压UBb、UBc、UCb。如果测得的电压大小符合表2的关系,即可判断其联接组标号。除上述试验外,变压器试验还有绝缘电阻测量、交流耐压试验等绝缘特性试验。进行型式试验中还需作温升试验、冲击电压试验等。在开发新产品时,通常需进行短路动稳定试验,用以与计算机的计算结果互相校核,以确定新产品耐受短路电动力的能力。
  

说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条