说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 定子接地保护
1)  stator ground protection
定子接地保护
1.
Analysis on misaction of 3ω stator ground protection for steam turbine-generators;
汽轮发电机三次谐波电压定子接地保护的误动分析
2.
Discussion on the setting calculations of stator ground protection based on the third-harmonic voltage criterion;
三次谐波电压型定子接地保护整定计算探讨
3.
The research and development on injection scheme for stator ground protection of 1000 MW generator;
百万千瓦机组注入式定子接地保护的研究与开发
2)  stator grounding protection
定子接地保护
1.
Reliability of stator grounding protection based on 3rd harmonic voltage;
提高三次谐波电压式定子接地保护动作可靠性的措施
2.
It determines if the grounding point is in generator stator winding according to the first harmonic and third harmonic of leaking current to realize 100 % stator grounding protection.
在深入分析发电机对地泄漏电流(即3倍中性点侧零序电流与机端出线侧零序电流之差)的基础上,提出了一种通过比较发电机定子单相接地故障时各发电机泄漏电流的大小或方向进行保护的发电机定子接地保护新方法。
3.
Security and stability problems were analyzed caused by generator rotor grounding protection,generator excitation-loss protection and stator grounding protection.
对发电机转子接地保护、发电机失磁保护、发电机定子接地保护在实际运行中存在的影响机组安全稳定运行问题进行了分析,并提出相应的改进措施。
3)  stator ground fault protection
定子接地保护
1.
The drawbacks of present stator ground fault protection principle for the small and medium sized generators are pointed out.
指出了现有中小型发电机定子接地保护原理的不足。
2.
The basic reason is that the load change causes the 3rd harmonic voltage changing of stator windings (EΦ3),so that the 100% stator ground fault protection based on the 3rd harmonic voltage will be influenced.
大型汽轮发电机机端3次谐波电压U3t以及中性点3次谐波电压U3n随有功负荷和无功负荷变动而变化,根本原因是定子绕组3次谐波电压EΦ3受负荷影响,从而影响到3次谐波电压的100%定子接地保护
4)  stator earth fault protection
定子接地保护
1.
A novel selective stator earth fault protection based on zero-sequence direction element is proposed, which can overcome the shortage of stator earth fault protection applied to generator connected as expanding unit.
指出现有定子接地保护应用于扩大单元接线方式发电机上的不足,提出基于零序方向元件的选择性定子接地保护方案。
2.
More and more large-sized generators are installed 100% stator earth fault protection with low-frequency alternating-voltage injection.
近年来越来越多的大型发电机装设100%注入式定子接地保护
3.
The mode of the connection not noly have a close relation to the generator stator earth fault protection,but also to the current of single phase connected to earth fault and the insulation of the stator.
发电机的中性点接地方式不仅与定子接地保护所采用的形式密切相关 ,而且与单相接地故障电流、定子绕组的绝缘相关。
5)  stator grounding fault protection
定子接地保护
1.
The stator grounding fault protection with 20Hz voltage injection can provide 100% winding s protection and monitor the drop of stator s insulation.
20Hz注入式定子接地保护可以单独实现定子100%绕组的保护,可以监测定子绝缘水平的下降,因而越来越多地应用于大型发电机保护。
6)  80% stator earth protection
80%定子接地保护
1.
The purpose for perfecting the principle objection of inter-turn and 80% stator earth protection is gained.
简要介绍了小浪底水电站数字式继电保护系统(DRS)的功能,通过增加电压闭锁功能,达到完善匝间保护和80%定子接地保护原理缺陷的目的,解决了匝间保护和80%定子接地保护误动现象,从而取得了良好的效果。
补充资料:电力系统中性点接地变压器接地


电力系统中性点接地变压器接地
earthing transformer for neutral grounding

d旧n]一x .tong之hongx旧gd一onj旧d一b旧nyoq一j旧d-电力系统中性点接地变压器接地(earthingtransformer for neutral grounding)电力系统中利用接地变压器获得中性点与大地连接,也称中性点辅助变压器接地。当系统中的变压器不具备接人电阻器或接地故障消除器的条件(例如变压器三相绕组为△接线或虽为Y接线但容量不符合要求)时,要利用辅助的变压器提供一个用于接地的中性点。这种变压器应具备零序阻抗低、激磁阻抗大、功率损耗小的特性。绕组为曲折(Z)接线的变压器符合要求,如图1(a)所示。它可以带二次侧绕组,也可以只有一次侧绕组。 这种变压器每相由匝数相等的两个串联分绕组组成,每个磁芯上的两个分绕组间以及它们对二次侧绕组的零序互磁为零。很明显,这种变压器的零序电抗XTo只为变压器一次侧绕组的漏电抗Xs,,即XTo-Xs;,而系统中性点与地之间的计算阻抗Z。为Z。一25,+Z。,其中Z。为中性点电阻器或电抗器的阻抗。见图1(b)。2.为激磁阻抗。见图2,YN,d接线的变压器二次侧绕组可以带一定负荷。从过负荷能力考虑已经知道.接YN,d接线的双绕组变压器中性点的接地设备的容t不应超过变压器额定容t的50%.由此可认为,当变压器额定容t按中性点接地设备的容t设计时,允许二次侧绕组带50%额定容t的负荷. 还有一种特殊接线的接地变压器和接地设备的组合,是1918年鲍赫(R.Bauch)发明的,故也称饱鹅变压器,见图3。变压器一次侧中性点直接接地,开口三角形接线的二次侧连接接地设备,这与一次侧中性点接有接地设备是等效的。单相接地时,不对称的电压可分解为对称的正序和零序,磁通也可分解为对应的分量。磁通人m、人。、人.需要极小的激磁电流,并对应于正序电压U.。、U、。、U。。,零序电压UO.对各相是一样的,故三个磁柱中有相同的磁通式,对零序磁通来说,变压器相当一个单相变压器,只不过分裂为3个磁柱和3个绕组,见图3(c)。单相接地时,这种变压器每个分绕组上的电压为少尹z‘一.哟.!|||一下咖l!补丰气l一!{屯犷!{屯享!孟=zl息)一刃川l|拍--l--﹄·图1绕组为曲折(Z)接线的变压器 (a)接线图.(b)零序阻抗图会‘价“相“压,·““”的““是中”点接地“备电流的1/3,即夸。因而变压器的额定功率为3x2‘会‘争即中性点接地设备“率”1.15倍。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条