1) T wave alternans
T波电交替
1.
A clinical study of microvolt T wave alternans and ventricular tachycardia;
微伏级T波电交替与室性心动过速的临床研究
2.
T wave alternans(TWA) is a marker of cardiac electrical instability with the potential for ventricular arrhythmia risk stratification among the high vulnerable patients and is considered as human and animals mark leading to ventricular tachycardia and ventricular fibrillation.
T波电交替是心肌电活动不稳定的标志,可作为室性心律失常高危患者的危险分层,是人类及动物缺血心肌发生室性心动过速、心室颤动的标志,是发生恶性室性心律失常及心性猝死的无创预测指标。
3.
The system devised by ourselves is used to detect the ECG signal, and transfer the T wave alternans from time domain to frequence domain .
同时引入 T波电交替系数 TWAI用于电交替的测定 ,其分析结果定量性较好 ,显著优于以前在心电图上肉眼观察的效果。
2) T wave alternation
T波电交替(TWA)
3) T wave alternans index
T波电交替系数
1.
At the same time, we introduce T wave alternans index (TWAI) as the standard measure index.
同时引入 T波电交替系数 TWAI用于电交替的测定 ,其分析结果定量性较好 ,显著优于以前在心电图上肉眼观察的效果。
4) T wave alternans
T波交替
1.
Objective To detect and analyse the TWA(T wave alternans,TWA) in angina patients.
目的检测与分析心绞痛患者的T波交替(Twave alternans,TWA)。
2.
Objective: To investigate whether the microvolt-level T wave alternans (TWA) alternating morphology from beat-to-beat during exercise chould be a marker to identify the high-risk of ventricular arrythmia in patients with ischemic heart disease.
目的:探讨微伏T波交替(TWA)可否作为一项缺血性心脏病患者伴室性心律失常危险因素的预测指标。
3.
Considerable scientific data support the potential value of T wave alternans(TWA) is ralated to ventricular arrhythmias and sudden cardiac death and provides a noninvasive and clinically useful marker for the risk of them.
T波交替(T-wave alternans,TWA)作为一种非稳态的心电变异性现象,是指心电T波段振幅、形态甚至极性逐拍交替变化。
5) T-wave alternans
T波交替
1.
ECG T-wave alternans detection using low sampling frequencies;
低采样率心电非稳态T波交替分析方法
2.
Objective:To research the technology of detecting T-wave alternans (TWA) which is a variation in the amplitude or morphology of the T wave of the beat-to-beat ECG.
方法:本研究首先使用Mexican-hat小波检测R峰并对心电信号进行预处理;在提取T波矩阵方面为减少心拍间内差,采用点乘最大法,最大程度地对齐T波;最后基于时域相关分析方法检测T波交替幅度、交替心拍,追踪非稳态心电信号中短暂的交替数据段。
6) TWA detection
T波电交替的检测
补充资料:厂用电受电
厂用电受电
energizing of auxiliary power system
chongyongd一on sho一Jd一on厂用电受电(energizing of auxiliary powersystem)机组附属设备安装完毕后需通电试运行,所需厂用电源由外部供给,因此厂用电受电是调试工作开始的标志。 受电步骤新建电厂先由电力系统向变电站供电,再依次对高压起动/备用变压器、3~10kv厂用配电装置、厂用工作变压器及380V配电装置供电。扩建电厂因高压起动/备用变压器已经投人运行,故可利用它的电源对扩建的厂用配电装置等供电。 调试项目主要有:①用额定电压依次对空载线路、变电站母线、隔离开关、断瘩器、互感器、变压器及厂用配电装置等进行冲击合闸试验。有条件时.冲击合闸前应先进行递升加压试验。升压过程中注意检查各设备有无放电声及短路现象,发现问题及时处理后再进行升压。②检查三相电压应平衡,相序应正确,各段母线的相位彼此应一致。对配电装置供电时,有时会由于母线电容和与母线连接的电磁式电压互感器的电感相互作用而出现铁磁谐振,此时相电压升高,中性点明显位移。为消除谐振可在电压互感器的剩余电压绕组处并联电阻以去振。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条