1)  Wavelength modulation
波长检测型传感器
2)  wave-length
波长
1.
Based on the CJ267-91,the text studies the effect of solvent,the preparation of the normative sample and the wave-length upon the result of mensurating mineral oils, so that it′s possible to choose the suitable condition to improve the accuracy of the mensurating results.
本文以CJ 2 6 7- 91为依据研究了溶剂、标准品的制备及波长三方面对测定矿物油类的影响 ,从而选择适宜的条件 ,提高了测定结果的准确度。
3)  wavelength
波长
1.
Determination of the Best Wavelength and Regression Equation of Ultra - Violet Spectrophotometer of 10 - Hy- droxy- Decenoic Acid (10 - HDA) in Pure Royal Jelly;
纯蜂王浆10-羟基癸烯酸紫外测定法最佳波长及回归方程的确定
2.
Influence of laser wavelength on depth of photoacoustic imaging;
激光波长对光声成像深度影响研究
3.
Effect of rail irregularity wavelength on lateral runningcomfort of speed-raised train;
线路不平顺波长对提速列车横向舒适性影响
4)  wave length
波长
1.
This paper presents the principle,formula derivation and detailed operation of an improved method for determining the asphaltene content through measuring the absorption degree of the sample suspension under incident beam of wave lengths of 750 nm and 800 nm.
介绍了一种用双波长分光光度法测定稠油中沥青质含量的改进法。
2.
The paper presents a mehtod for determining the wavelength of shallow water waves by using the wave dispersion equation and the influence of water depth,water flow, and wave amplitude upon the wave lengt
介绍了用波浪弥散关系确定浅水波长的方法 ,讨论了水深、水流、波浪振幅对波长的影
3.
Thestandard optical pyrometer of this pyrometers is the standard instrument used at thehigh temperature zone of the international practical temperation scale,But wanting to have the meas-ured temperature,the value of the effective wave length must be determined.
光学辐射高温计是高温测量中精度最高的仪器,其中的基准光学高温计是国际实用温标高温区的标准仪器,但欲得到被测温度,需确定有效波长值,本文探讨了影响有效波长的因素及其计算方法,并讨论了它对测量精度的影响。
5)  double-wavelength
双波长
1.
Absorbency at wavelength 510 nm and 390 nm were determined respectively with double-wavelength spectrophotometry,then iron and titanium in sample solution were detected.
分别在波长510nm和390nm测其吸光度,用双波长计算法,同时测定试液中的铁和钛。
2.
Methods:According to UV spectral properties of 2-MN and 2-MNQ in anhydrous alcohol, the equivalence absorbency double-wavelength UV spectrophotometry was adopted, and 275.
方法根据2-MN和2-MNQ在无水乙醇溶液中的光谱特征,采用等吸收点双波长法,选择275。
3.
A double-wavelength spectrophotometry was used to determine the Co~(2+) and Ni~(2+) content in nickel-cobalt alloy electrolyte simultaneously,using PAR-ethanol solution as developer.
提出采用双波长分光光度法同时测定镍钴合金镀液中Co2+与N i2+的含量。
6)  λ=wavelength
λ=波长
参考词条
补充资料:气体检测传感器的检测原理
检测气体的浓度依赖于气体检测变送器,传感器是其核心部分,按照检测原理的不同,主要分为金属氧化物半导体式传感器、催化燃烧式传感器、定电位电解式气体传感器、迦伐尼电池式氧气传感器、红外式传感器、PID光离子化传感器、等以下简单概述各种传感器的原理及特点。

金属氧化物半导体式传感器 
    金属氧化物半导体式传感器利用被测气体的吸附作用,改变半导体的电导率,通过电流变化的比较,激发报警电路。由于半导体式传感器测量时受环境影响较大,输出线形不稳定。金属氧化物半导体式传感器,因其反应十分灵敏,故目前广泛使用的领域为测量气体的微漏现象。

催化燃烧式传感器。 
    催化燃烧式传感器原理是目前最广泛使用的检测可燃气体的原理之一,具有输出信号线形好、指数可靠、价格便宜、无与其他非可燃气体的交叉干扰等特点。催化燃烧式传感器采用惠斯通电桥原理,感应电阻与环境中的可燃气体发生无焰燃烧,使温度使感应电阻的阻值发生变化,打破电桥平衡,使之输出稳定的电流信号,再经过后期电路的放大、稳定和处理最终显示可靠的数值。

定电位电解式气体传感器 
    定电位电解式传感器是目前测毒类现场最广泛使用的一种技术,在此方面国外技术领先,因此此类传感器大都依赖进口。定电位电解式气体传感器的结构:在一个塑料制成的筒状池体内,安装工作电极、对电极和参比电极,在电极之间充满电解液,由多孔四氟乙烯做成的隔膜,在顶部封装。前置放大器与传感器电极的连接,在电极之间施加了一定的电位,使传感器处于工作状态。气体与的电解质内的工作电极发生氧化或还原反应,在对电极发生还原或氧化反应,电极的平衡电位发生变化,变化值与气体浓度成正比。

迦伐尼电池式氧气传感器 
    隔膜迦伐尼电池式氧气传感器的结构:在塑料容器的一面装有对氧气透过性良好的、厚10~30μm的聚四氟乙烯透气膜,在其容器内侧紧粘着贵金属(铂、黄金、银等)阴电极,在容器的另一面内侧或容器的空余部分形成阳极(用铅、镉等离子化倾向大的金属)。用氢氧化钾。氧气在通过电解质时在阴阳极发生氧化还原反应,使阳极金属离子化,释放出电子,电流的大小与氧气的多少成正比,由于整个反应中阳极金属有消耗,所以传感器需要定期更换。目前国内技术已日趋成熟,完全可以国产化此类传感器。

红外式传感器 
    红外式传感器利用各种元素对某个特定波长的吸收原理,具有抗中毒性好,反应灵敏,对大多数碳氢化合物都有反应。但结构复杂,成本高。

说明:补充资料仅用于学习参考,请勿用于其它任何用途。