1) Standard addition method
标准溶液加入法
1.
Methods:The samples were injected into HP-5 capillary colnmn by head- space sampler and analysed with FID detector with standard addition method.
方法:用 HP-5毛细管气相色谱柱,顶空进样,FID 检测器,以标准溶液加入法进行计算。
2) Standard addition
标准加入法
1.
Rapid determination of the Fe and Cu in acrylonitrile and acetonitrile by ICP-MS with ORS by standard addition was reported.
采用带八级杆碰撞/反应池(ORS)的电感耦合等离子体质谱法(ICP-MS),直接测定丙烯腈或乙腈产品中的Fe、Cu,标准加入法定量。
2.
Quantitative analysis is depended on standard addition r>0.
用ICP-AES仪以标准加入法建立的直线为定量标准曲线同时测定亚硫酸氢钠中微量铁、砷和铅。
3.
Standard addition method and analysis correction cure method were the two simple and fast ways to check disturbance.
介绍了原子吸收光度法中的光谱干扰和非光谱干扰,指出标准加入法和分析校准曲线法是消除和减少某些干扰最简单、快速的校准方法。
3) standard additions
标准加入法
1.
Using standard additions and Zeeman effect background correction,the linear range of Pb content was between 10 to 50 μg/L,and the recovery rate was 90%~110%.
研究了石墨炉原子吸收法测定葡萄酒中微量铅的适宜条件,采用标准加入法和塞曼效应校正背景,铅的线性范围为10μg/L~50μg/L,回收率为90%~110%。
2.
Analytical results were calculated via the method of standard additions.
利用标准加入法和塞曼效应校正背景,铅的线性范围为0~50μg/L,回收率为90%~110%。
3.
Determination of Manganese,Lead and Copper in Distilled Spirit by ICP-MS with Standard Additions;
在 ICP- MS基础上用标准加入法对白酒中的锰、铅、铜进行了定量测定。
4) standard addition method
标准加入法
1.
Determination of trace Pb in sufu by GFAAS using standard addition method and ascorbic acid as matrix modifier;
标准加入法-抗坏血酸基体改进剂GFAAS测定腐乳中痕量铅
2.
Solving problems of standard addition method in instrumental analysis teaching;
标准加入法在仪器分析中的应用释疑
3.
Determination of urease activity of the soil using ammonia gas sensor-standard addition method;
氨气敏电极-标准加入法测定土壤脲酶活性
5) standard adding method
标准加入法
1.
The standard adding method can eliminate the interference of basal effects.
标准加入法可以消除基体效用所产生的干扰,该法简单、快速、重现性好、灵敏度高、线性范围宽,成功地应用于苦瓜提取物总黄酮含量的测定。
2.
Mathematic model was used to deduce the measurement error formula of standard adding method for atomic emission spectrum.
利用数学模型推导出了原子发射光谱标准加入法的测量误差公式 ,证明在第一次加入的被测元素标准含量等于待测试样中被测元素含量时这种误差最
3.
This article start with the basic principle of optical analyzing method, introducing standard curve method , standard adding method,unitary method ,exte.
临床光学仪器分析方法是基于常规实验数据处理方法,本文从光学分析方法的基本原理入手,介绍了标准曲线法、标准加入法、归一法、外标法和内标法、终点法。
6) standard addition calibrating technique
标准加入校准法
补充资料:标准溶液加入法
分子式:
CAS号:
性质:又称标准(溶液)加入法。X射线荧光分析试样中待测元素含量低于5%~10%时所用的一种定方法。其方法与原子发射光谱增量法操作相同,仅所加入待测元素的含量应比试样含量增大1至3倍。以加入量为横坐标,荧光强度为纵坐标绘制校准曲线。
CAS号:
性质:又称标准(溶液)加入法。X射线荧光分析试样中待测元素含量低于5%~10%时所用的一种定方法。其方法与原子发射光谱增量法操作相同,仅所加入待测元素的含量应比试样含量增大1至3倍。以加入量为横坐标,荧光强度为纵坐标绘制校准曲线。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条