2) MRM
多反应监测
1.
Multi-reactions monitoring (MRM) technology of triple-quadrupole tandem mass spectrometer, positive scan mode was employed.
使用三级四极串联质谱(MS/MS)的多反应监测(MRM)技术,正离子采集模式,监测转换离子对m/z277→259,以MRM离子流峰面积作为定量依据。
2.
Analytes identification and quantification were performed using multiple reaction monitoring (MRM) with one precursor ion and three to four product ions as identifiers and electrospray ionization in positive mode.
采用微量化样品前处理技术,以固相萃取为净化方法,电喷雾正离子多反应监测方式建立了尿样及动物组织中β 兴奋剂残留量的液相色谱-串联质谱联用测定法。
3.
Methods:Using multi-reactions monitoring (MRM) technology of triple-quadrupole tandm mass spectrometer to determine.
方法:使用四级串联质谱(MS/MS)的多反应监测(MRM)技术测定。
3) Multiple reaction monitoring
多反应监测
1.
Analytical identification and quantification were performed using multiple reaction monitoring(MRM) and electrospray ionization in negative mode.
采用C18 SPE萃取小柱净化蜂王浆样品,以电喷雾负离子多反应监测方式进行定性定量分析,并优化了提取、净化及仪器各项参数,测定结果重复性较好,氯霉素残留量在(0。
2.
Analyte identification and quantification were performed using multiple reaction monitoring with one precursor.
本文建立了一种两步法分离纯化试样、基于LC /MS /MS技术多反应监测的卷烟主流烟气中N-亚硝基降烟碱(NNN)、4-(N-甲基亚硝氨基)-1-(3-吡啶基)-1-丁酮(NNK)、N-亚硝基新烟草碱(NAT)和N -亚硝基假木贼碱(NAB )4种主要TSNAs组分同时测定的方法。
3.
Chloramphenicol in shrimps was extracted by ethyl acetate under ultrasonication,and determined by high performance liquid chromatography using methanol as the mobile phase,detected by multiple reaction monitoring (MRM) mode with m/z 321/152 ions as a monitoring ion pair.
采用乙酸乙酯超声提取对虾组织中的氯霉素残留 ,以甲醇为流动相 ,选择m/z 32 1/15 2为氯霉素的检测离子对 ,用多反应监测 (MRM )技术测定。
4) selected reaction monitoring
选择反应监测
1.
A 15-m GC column,tandem mass spectrometry with selected reaction monitoring along with the internal standard method were used to analyze from tri-to hepta-BDEs and deca-BDE,The detection limits of PBDEs were 0.
对6份南京实际大气样品的检测结果表明:离子阱质谱的选择反应监测(selected reaction monitoring,SRM)技术能有效的降低背景干扰。
5) Reactivity monitoring techniques
反应监测技术
6) MRM
多离子反应监测
1.
Determination of 16 PAHs in Soil by ASE-GC/MSMS MRM;
ASE-GC/MSMS多离子反应监测(MRM)测定土壤中的16种多环芳烃(PAHs)
2.
microcystin-LR was determined by UPLC-ESI-MS/MS and quantified with multiple reaction monitoring(MRM) mode.
2μmGHP一次性针头过滤器过滤,应用超高效液相色谱/电喷雾串联四极杆质谱仪多离子反应监测(MRM)法定量检测MC-LR。
补充资料:反应堆仪表监测系统
反应堆仪表监测系统
reactor instrumentation monitoring system
fany一ngduly一b一00]一oneex一tong反应堆仪表监测系统(reactor instrumenta-tion monitoring system)用以在正常运行和事故工况下监测反应堆工作状况的仪表系统。反应堆仪表监测系统检测反应堆内核裂变反应过程.检测热能在堆内传递的热工过程.并监测与反应堆组成部件工作状态有关的各种参数,及时向主控制室提供反应堆运行或事故工况下的全部信息,并向反应堆控制系统和保护系统提供相应的信号。 反应堆仪表监测系统的组成与堆型有关。就压水堆而言,有核功率测1系统,堆芯测t系统,控制捧位1指示系统,以及事故后监测系统等四部分。对压力管式反应堆来说.它由大量相同的工艺单元组成,为此设t工艺管成群监测系统。除了直接的物理量监测系统外,一般还设有间接物理量监测装置。 核功率测t系统由布置在堆芯四周的探侧器和测量仪表组成。通过检测堆芯外的中子注t率来检侧反应堆在起动、正常运行和停闭时的功率及其变化速率。设有专用的探测器,用以为反应堆功率调节系统提供中子注量率水平信号。另设有一些专用探测器为反应堆保护系统提供超功率、功率倾斜或短周期等保护信号。 堆芯测t系统由堆芯中子注1率浏童系统和堆内沮度浏圣系统组成。 (”堆芯中子注量率测量系统。由设里在姗料组件测量管道中的微型裂变室、微型裂变室传动机构及测量仪表组成.用以检测堆芯不同部位、不同高度的中子注t率水平,监察堆芯功率峰值,并为验证堆芯物理性能,以及燃料管理提供实侧数据。 (2)堆内温度侧t系统.由设里在嫩料组件靠近冷却剂出口处的热电偶、引出电缆及侧量仪表组成,用以检测反应堆径向不同部位不同嫌料组件的温度值,监察嫩料组件的过热。 控制棒位!指示系统用以检侧各类控制棒在堆芯中的位t,并在主控制室显示每组控制棒的插人深度,以便于操纵员调整控制棒的插人深度,保持合理的堆芯中子注量率分布。 事故后监测系统系美国三里岛核电厂事故后发展起来的系统,主要用于监察失水事故后堆芯是否具备充分的冷却条件,主要的监侧参数有反应堆压力容器中的水位和反应堆出口冷却剂的欠热度。 工艺管成群监测系统通常设有工艺管冷却剂进口流t、出口温度监侧,石墨气冷堆还设有元件表面温度监测,以监察工艺管及其嫩料元件的运行状况。 间接物理t测t系统除了直接的物理量监测系统外,为了便于对反应堆工作状态的监察,近年来还开发了间接物理量监侧装里,如反应性模拟器、偏离泡核沸腾(DNB)比等。 反应性模拟器是利用点中子动力学模型,将反应堆中子注t率的变化反演为反应性参量。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条