1) lightningprematureexplosion
雷击早爆
2) early blasting of thunder
雷电早爆
3) lightning
[英]['laɪtnɪŋ] [美]['laɪtnɪŋ]
雷击
1.
Analysis of Lightning Failure of No. 2214 Disconnector in 220kV Baohe Substation in Chengde Area;
承德暴河220kV变电站2214断路器雷击故障分析
2.
The Transient Analysis for Lightning Surge of Transmission Line Tower;
输电线路杆塔遭受雷击时的瞬态特性分析
3.
Discussion on transmission line lightning fault detection
输电线路雷击故障查找探讨
4) Lightning strike
雷击
1.
Lightning strike category and integrated lightning protection technologies;
雷击种类及其综合防护技术浅析
2.
Analysis and Protection Measurement for Lightning Strike Accident in Wind Farm
风电场雷击事故的分析及防范措施
3.
At present more troubles in the transmit electricity line skit brake is caused by lightning strike,in the view of this phenomenon,combines with carrying out the lightningproof measures of 35 kV transmit electricity line in Xingtai Mine,the lightningproof technology was analysed.
针对目前雷击引起的输电线路跳闸故障较多的现象,结合邢台矿35 kV线路防雷措施的具体实施,对防雷技术进行了分析。
5) lightning stroke
雷击
1.
Analysis of a group of lightning stroke injury;
一组雷击病人的伤情分析
2.
Based on the practical situation of lightning protection in these oil stations,this paper presents the forming cause,influence and dangers of lightning stroke,and explicates the types,principle of work,installation requirements of the lightni.
目前,现有的石油天然气井站为了避免采输设备、电气设施遭雷击或爆炸,不仅安装了避雷针,而且对各类设备还做了接地等防雷防爆处理。
3.
Aimed at difficulties in locating the lightning stroke point and ascertaining the pattern of stroke currently,monitoring and gauging methods for stroke to transmission line and over-head ground line,current path in tower and insulator string flashover path are achieved through studies on current path under stroke to transmission line and calculating current under stroke to tower.
针对当前架空输电线路雷击点的查找和雷击形式判断难题,通过对雷击输电线路电流路径研究和雷击杆塔仿真计算,得出了雷击导地线、杆塔电流路径和绝缘子串闪络监测及判别方法,研制了可快速分析判断雷击线路杆塔号、雷击地线或导线相别、位置、雷电流极性和雷击形式的雷电流幅值、时间和波形等参数的实时监测系统。
6) Lighting strike
雷击
1.
The discussion about the dependability of lighting strike OPGW;
OPGW雷击可靠性研究
2.
Study on transient characteristics of HV over-head transmission lines due to lighting strikes is significant to reliability improvement of protection and wave-location device that based on transients.
通过研究输电线路雷击的特点,利用小波变换分析雷击故障暂态电流和短路故障电流在暂态特性方面的差异,可以实现对雷击故障的识别。
补充资料:早爆
早爆
premature explosion
200匕00早爆(下)ron、ar盯e explosion)实施爆破前发生的意外爆炸早爆事故的频率在各种意外爆炸中占首位,其原因是人的过失和环境牛扰 人为过失胜早爆爆破器材是相对稳定的化学体系,由于过失性操作使其受到过强的冲击、摩擦或火焰作用,就会发生早爆。将各种爆破器材的敏感性做定量比较,结合事故统计分析,形成了危险性分类的安全操作规则,为减少这类早爆提供了技术依据。 环境干扰早爆引起早爆的环境因素有雷电和机电设备产生的杂散电(见杂散电流引爆)、静电、射频电和感应电。(l)雷电能引起任何电雷管和非电雷管甚至炸药早爆,雷电场还能引起雷击点周围的导体回路产生很强的感应电流,使电雷管早爆。按场强和闪电频率变化来预报雷电的预报仪,能提前发出警报,以便及时停止操作,撤离危险区。(2)静电产生于用压缩空气向炮孔装填粉粒状炸药的过程中.压气装药的静电可积累在装药器、操作者手上、炮孔内和雷管脚线卜.电压可达30一6()kV静电放电可以两种方式点燃雷管:放电电流经过脚线加热雷管的电桥丝或脚线头与雷管壳间击穿时点燃引火头;前者的最小静电点燃能量为4一10mJ;后者为巧一8()mJ。恶劣条件下压气装药的静电放电能量远大十上述点燃能量,甚至能点燃非电雷管。采取半导电输药管,装药器良好接地,控制装药速率和压缩空气的绝对湿度可减少静电危险。(3)射频电从雷管引出的两条电线同时伸展,形成偶极天线,容易接收调频的电视射频能,电线总长度为L一 几n亏时接收的能量最大,式中几为波长,m;。为正整数.,,一l、2、3、…;雷管的一条电线接地,一条电线伸展所形成的天线,容易接收中短波调幅射频能,伸展电线的长度为:一手时接收至。的能量最大。(4)感应电高压输电线在电爆网路中感生的电能,电爆网路与输电线平行且形成环的面积越大,感生电势越强。故在高压线附近进行电爆破时、爆破电线应尽量靠拢,其方向应尽量垂直于输电线,以减少早爆危险。 (徐天瑞)
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条