1) large spherical holder
大型液化石油气球罐
1.
Safety design policy of large spherical holder for liquefied petroleum gas;
大型液化石油气球罐的安全设计对策
2) LPG Spherical tank
液化石油气球罐
1.
The safety measures of prevention and control for leakage of LPG spherical tank;
液化石油气球罐泄漏危险的预防和控制探讨
2.
The reasons for crack appearance in LPG spherical tank and the methods for prevention.
介绍液化石油气球罐检验中裂纹形成原因及预防措施。
3) PLG spherical tank
石油液化气球罐
1.
By analyzing the problems existing in the leakage emergency handling measures for the bottom flange of a PLG spherical tank, the design of process pipeline at the bottom of the PLG spherical tank was improved, and the corresponding emergency handling measures were put forward.
通过分析普通石油液化气球罐底法兰泄漏应急处理措施存在的弊端,对石油液化气球罐底工艺管道设计进行了改进,提出相应的应急处理措施,从根本上解决了球罐底法兰发生泄漏的问题。
4) large-scale LPG spherical tank
大型液化气球罐
1.
It can instruct the material selection, design and construction of large-scale LPG spherical tank.
对我国大型液化气球罐的选材、设计及建造有一定的指导作
5) LPG tank
液化石油气储罐
1.
Advances in investigation of response pattern of LPG tanks exposed to fire;
液化石油气储罐在火灾下的响应规律研究进展
2.
The crackle of a 100m3 LPG tank was analyzed.
通过对1台100m3液化石油气储罐产生裂纹的分析,指出应力腐蚀、在用脆性裂纹及残余应力是产生该台液化石油气储罐裂纹的直接原因;并提出预防裂纹产生的措施。
3.
Thecauses of LPG tank inactivation which is in fire hazard environment are simply analysed fromtwo aspects, the inside factor (heat transfer and stress) and outside factor (fragment impact) ofthe tank, and do numerical simulation base on it with ANSYS and ANSYS LS-DYNA.
通过对相关理论进行分析的基础上,分别从内部因素(传热行为和应力分析)和外部因素(破片撞击)两个方面对火灾环境下液化石油气储罐的失效过程进行探讨,并借助ANSYS和ANSYSLS-DYNA软件对其进行数值模拟。
6) LPG tank
液化石油气贮罐
1.
In this article,the reform of the flange joint at the bottom of LPG tank was introduced,and the methods to remove leakage were discussed as well.
介绍了液化石油气贮罐根部法兰组合改造情况,并探讨根除泄漏的方法。
补充资料:气球通信
气球通信
balloon communication
qiqiu tongxin气球通信(balloon eommunieation)以系留气球作载体,将通信设备升至空中进行的无线电通信。又称系留气球通信。一般工作在超短波、微波波段。系留气球上的通信设备可以作为中继站传输电话、电报、数据和图像信息;也可作为无线电通播使用;还可以用于远程超视距电子侦察、监视、警报及通信干扰等。气球通信系统主要由气球中继站、地面终端站及控制站等组成(见图)。气球中继站由气球、通信设备、系留绳索及系留设施等构成。为减小气流的影响,将气球设计成飞艇状,便于在空中悬停,为球载通信设备提供稳定的空中工作平台。通信设备集中悬挂在气球下方的防风罩内。球体的截面直径一般为数米至数十米,长度为数十米,球内通常充以氦气。气球用绳索系留稳定在3 000一5 000米乃至更高的高空,有效载重量可达数吨。系留绳索主要由多股绞合的铜线电缆和光导纤维组成。电缆为供电馈线;光导纤维作为遥测、遥控的传输线。小型气球的地面系留设施是固定在越野的平板拖车上,大型的固定在地面上。通信距离由气球的高度决定,例如,通过3千米高空的系留气球转信,地面终端站之间的通信距离可达400千米。若利用多个气球接力,还可增大通信距离。气球通信的优点是通信距离远,覆盖面积大;投资少,效率高;通信质量好、容气球中继站一件- 气球通信系统组成示意图量大;设备简单,维修方便,使用安全,适用于移动通信,特别是部队开进中的通信。缺点是供电较困难,目标较大。 (王运法)