说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 接地线
1)  grounding line
接地线
1.
This paper re_defines the grounding line (GL) of Amery Ice Shelf (AIS),East Antarctica,utilizing radio echo sounding (RES) data.
根据无线电回波测厚 (RES)数据对东南极Amery冰架与陆地冰分界线进行了重新划定 ,指出该冰架的接地线位置最南一直向内陆延伸到 73 。
2.
Effect of grounding line on transformer winding deformation test was described in this paper.
阐述了接地线对变压器绕组变形试验的影响,提出了解决接地线对变压器绕组变形试验影响的一些方法。
3.
The hanging and removing of grounding line of contact system is the chief problem to insure the security of overhaul operators and power equipment.
接触网接地线正常挂接工作并及时拆除是保证检修作业人员和设备安全的首要问题。
2)  Earth wire
接地线
1.
of precision electric measuring system,analyzing at length the effects of earth wire,electric field noise and magnetic field noise on the measuring results.
详细分析了接地线、电场噪声、磁场噪声对测量结果的影响,并提出解决问题的办法和保护措施。
3)  grounding wire
接地线
1.
Proper use of portable shorting grounding wires;
关于正确使用携带型短路接地线的探讨
2.
The fault caused by the improper installation of the grounding wire of the splices in 110 kV HV cables lines in Nanjing District is analysed.
对南京地区110kV高压电缆线路电缆连接头的接地线安装施工质量引起的电缆故障进行了分析,提出了相应的措施,避免了类似故障的发生。
4)  ground wire
接地线
1.
Through comparing the residential electric design standards in our country with those in foreign countries,this essay focuses on discussing the residential electric charge standard in our country and the design of the capacity of indoors wire,branch wire section,branch return circuit and ground wire,etc.
比较了国内外住宅电气的设计标准 ,论述了我国民用住宅电气用电负荷标准、进户线和分支线截面、分支回路接地线等容量的设计 。
2.
According to the GB requests,the domestic electric washing machine\'s plug must have the ground wire.
根据国标要求,家用电动洗衣机的电源线组件必须有接地线
5)  earth line
接地线
1.
An electronic management display system of grounding status in substation is studied, which is to prevent two kinds of mal-operation of closing grounding-switch and articulating earth-line, sending the electricity by taking electricity with grounding switch and closing earth line.
为防止在变电站中带电合接地刀闸、挂接地线与带电接地刀闸、接地线合闸送电2类误操作事故,研制了一种变电站接地状态电子管理显示系统。
2.
Therefore, the earth lines for substations and electric power lines of Taishan Power Bureau were modified utilizing microcomputerized anti maloperation devices and mechanical program locks, thus enabling blocking function and retaining the flexible usability.
无五防装置的接地线 ,容易造成误操作。
6)  grounding [英]['ɡraʊndɪŋ]  [美]['graundɪŋ]
接地;地线
补充资料:电力系统中性点接地变压器接地


电力系统中性点接地变压器接地
earthing transformer for neutral grounding

d旧n]一x .tong之hongx旧gd一onj旧d一b旧nyoq一j旧d-电力系统中性点接地变压器接地(earthingtransformer for neutral grounding)电力系统中利用接地变压器获得中性点与大地连接,也称中性点辅助变压器接地。当系统中的变压器不具备接人电阻器或接地故障消除器的条件(例如变压器三相绕组为△接线或虽为Y接线但容量不符合要求)时,要利用辅助的变压器提供一个用于接地的中性点。这种变压器应具备零序阻抗低、激磁阻抗大、功率损耗小的特性。绕组为曲折(Z)接线的变压器符合要求,如图1(a)所示。它可以带二次侧绕组,也可以只有一次侧绕组。 这种变压器每相由匝数相等的两个串联分绕组组成,每个磁芯上的两个分绕组间以及它们对二次侧绕组的零序互磁为零。很明显,这种变压器的零序电抗XTo只为变压器一次侧绕组的漏电抗Xs,,即XTo-Xs;,而系统中性点与地之间的计算阻抗Z。为Z。一25,+Z。,其中Z。为中性点电阻器或电抗器的阻抗。见图1(b)。2.为激磁阻抗。见图2,YN,d接线的变压器二次侧绕组可以带一定负荷。从过负荷能力考虑已经知道.接YN,d接线的双绕组变压器中性点的接地设备的容t不应超过变压器额定容t的50%.由此可认为,当变压器额定容t按中性点接地设备的容t设计时,允许二次侧绕组带50%额定容t的负荷. 还有一种特殊接线的接地变压器和接地设备的组合,是1918年鲍赫(R.Bauch)发明的,故也称饱鹅变压器,见图3。变压器一次侧中性点直接接地,开口三角形接线的二次侧连接接地设备,这与一次侧中性点接有接地设备是等效的。单相接地时,不对称的电压可分解为对称的正序和零序,磁通也可分解为对应的分量。磁通人m、人。、人.需要极小的激磁电流,并对应于正序电压U.。、U、。、U。。,零序电压UO.对各相是一样的,故三个磁柱中有相同的磁通式,对零序磁通来说,变压器相当一个单相变压器,只不过分裂为3个磁柱和3个绕组,见图3(c)。单相接地时,这种变压器每个分绕组上的电压为少尹z‘一.哟.!|||一下咖l!补丰气l一!{屯犷!{屯享!孟=zl息)一刃川l|拍--l--﹄·图1绕组为曲折(Z)接线的变压器 (a)接线图.(b)零序阻抗图会‘价“相“压,·““”的““是中”点接地“备电流的1/3,即夸。因而变压器的额定功率为3x2‘会‘争即中性点接地设备“率”1.15倍。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条