1) air-cooled heat pump
风冷热泵
1.
Modification of small-sized air-cooled heat pump s orificeset and researing of energy-saving;
小型风冷热泵节流装置改造的节能研究
2.
Control noise of air-cooled heat pump;
风冷热泵机组噪声的治理
2) air cooled heat pump
风冷热泵
1.
Through the calculations, this paper analyzes the feasibility of the application of the air cooled heat pump units in Ningbo Area, gives out the cal culating methods, and discusses the problems that should be noticed during the p rocess of the application of the air cooled heat pumps.
通过计算,分析了在宁波地区应用风冷热泵机组的可行性并给出了计算方法,讨论了选用风冷热泵时应注意的问题。
2.
A Back Propagation Network was built to choose proper air cooled heat pump systems.
该文针对风冷热泵的选型设计建立了BP(Back PropagationNetworks)反向传播神经网络模型 ,网络模拟采用 3层前馈结构 ,输入层和输出层分别有 6个神经单元组成 ,隐含层结点数采用 1 5个。
3.
Comparing with the static design method, the excellences at the dynamic emulation and design about the underground buildings air cooled heat pump systems were shown.
针对地下建筑风冷热泵空调系统的特点 ,编制了UBHPAC应用软件 ,对单建式或附建式多房间地下设施进行了动态模拟 ,并与静态设计方法进行比较 ,指出了地下建筑风冷热泵空调系统的仿真与动态设计的优越性。
3) Air Source Heat Pump
风冷热泵
1.
The Study of the Air Source Heat Pump during the Reverse—Cycle Bypass Defrost;
风冷热泵旁通除霜问题的研究
2.
The reasons were analyzed from the points of how efficiently GSHP uses the underground thermal energy and EER comparison of GSHP with the air source heat pump.
通过比较土壤源热泵系统与风冷热泵系统的耗能量和土壤源热泵系统如何有效地利用地表热能两个方面,分析了土壤源热泵系统节能的原因并提出了影响其节能特性的因素。
4) air-source heat pump
风冷热泵
1.
Heating performance analysis of air-source heat pump chiller with refrigerant R410A at varied environment temperature;
R410A风冷热泵冷热水机组变环境温度制热运行特性分析
2.
This article has made a full analysis to the small temperature difference between intlet and outlet water of air-source heat pump which is located in Xianlin School district of Nan jing normal University.
对南京师范大学仙林校区的B1楼的风冷热泵机组主机的进出水温差过小的问题作了全面的分析,并提出了系统改造措施,收到了较好的效果。
5) air cooled heat pump unit
风冷热泵机组
1.
Analyses measured results of air cooled heat pump units operating in Xi'an , gives some points for consideration in design, installation and adjustment.
分析了风冷热泵机组在西安地区冬季运行的测定结果,探讨了设计、安装与调试需注意的事项,得出了在西安地区,对室内热环境要求不太高的中小建筑适于使用风冷热泵机组的结论。
2.
The working principle of the air cooled heat pump unit is introduced and problems are brought forth when designing and choosing the unit,such as amending the cooling (heating) capacity of the unit in specific ambient temperature,choosing the cooling(heating) capacity of the unit and installing the unit.
阐述了风冷热泵机组的工作原理及设计选型时依具体环境对机组制冷 (热 )量的修正、冷 (热 )负荷的选择及安装等方面应该注意的问题 ,特别是安装在积雪和台风地区时 ,应采取的防护措
6) air-cooled heat pump
风冷热泵机组
1.
The mathematical model of condenser of air-cooled heat pump was built.
建立了风冷热泵机组冷凝器的数学模型,分析了风量调节方式对COP的影响,得到不同工况不同负荷率下的最优风量变化曲线。
2.
Based on thermal economics the author analyses the air-cooled heat pump, and compared it with other cold (heat) sources.
利用热经济学的方法对风冷热泵机组进行了分析,并与其它较常用的两种冷热源形式进行了比较。
3.
Briefly gives an outline of the working theory of air-cooled heat pumps,and analyses the effect of ambient temperature in winter on heating capacity of these units .
简要介绍了风冷热泵的工作原理 ,分析冬季环境温度对热泵供热能力的影响 ,提出了布置风冷热泵机组要注意进排风通畅 ,避免气流短路和热泵运行的特
补充资料:隔膜泵与柱塞泵在涂装机械中的比较
高压无气喷涂效率高,表面细腻平整,附着力强,涂料损耗少而得到建筑机械 船舶 家具等行业的广泛使用。
高压无气喷涂机分为气动式无气喷涂机,电动式无气喷涂机(柱塞泵)和电动无气喷涂机(隔膜泵),由于气动式无气喷涂机需要带压缩空气源而限制了气动喷涂机的使用。
现仅将电动柱塞无气喷涂机与电动隔膜无气喷涂机作比较,柱塞泵是将直流电动机带动柱塞复运动将涂料吸入,加压后排出,由于其柱塞裸露,且柱塞在涂料中工作,在涂料研磨作用下柱塞磨损非常快,一旦配备口径较大的喷嘴,其柱塞往复频率提高,加剧柱塞的磨损,机器寿命短。而更换柱塞价格非常昂贵,如果电压不正常也将直接导致工作直流电的不正常。另外,由于大幅来回往复运动,柱塞泵的工作脉动很大,使得喷涂不稳定,涂料喷上的墙面平整度就不够好。但柱塞泵初始吸料较快是其长处。
隔膜式无气喷涂机(隔膜泵),其设计是在柱塞泵基础上得到了更大的改进,原理为用电动机带动活塞往复工作(注意,活塞并不直接接触涂料),再推动隔膜运动,将涂料吸收加压后推出,通过喷嘴喷向涂装物体,由于其活塞在防磨损的油中工作,工作环境大大优化,寿命大大提高,经过掺透硬化处理的活塞更是不易损坏,加上高分子材料制成的高抗绞隔膜更使隔膜泵寿命进一步提高。运行可靠是隔膜泵的又一长处,故障率极底,对电压要求底,对环境要求底,维修容易,维修费用仅为柱塞泵的五分之一左右。