说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 消防水
1)  Fire water
消防水
1.
This paper disecusses the calculation of elevated water tank volume,the measuresof keeping fire water demand volume and the installation location of elevated water tank.
探讨了多层商住楼高位水箱容积计算、保证消防水容积的措施以及高位水箱安装高度与位置,并结合实际工程,提出了高位水箱设置的最佳位置和解决市政供水量、水压周期性不足的最佳供水方案。
2)  fire pool
消防水池
1.
The Numerical Analysis about the Operating Characteristics of the Fire Pool in the GSHP System;
消防水池在地源热泵系统运行特性的数值分析
2.
Reform engineering experience of fire pool for water storage;
消防水池水蓄冷改造工程经验
3.
According to the problems existing in the water system for fire-fighting in residential area of common civil,the paper puts forward some improvement measures such as correctly selecting fire plugs,establishing fire pools,setting up long buttons,calculating the water consumption to improve the fire demand system around the area.
文章根据普通住宅小区消防给水系统存在的问题,提出了一些改进措施,即正确选用消火栓、设立消防水池、设远程启泵按钮、提前计算用水量来改善小区建筑内外消防给水系统。
3)  fire water supply
消防给水
1.
Discussion on the problems of fire water supply in the small-scale LPG storage and distribution station;
小型液化石油气储配站消防给水存在问题及改进
2.
The problems and solutions on fire water supply of cold area;
严寒地区消防给水存在的问题及对策
4)  fire tank
消防水箱
1.
Author points out that the calculation of the altitude of fire tank should take the working pressure of sprayer in the worst-case location in consideration,which should not less than 0.
结合工程实例,对多层建筑室外消防给水管网设计流速的确定进行了分析计算,并对临时高压自动喷水灭火系统高位水箱设置高度的确定进行了阐述,指出两位消防水箱的设置高度应以最不利点喷头工作压力不小于0。
2.
Combined with management practice of fire-fighting engineering of five high-rise buildings in one residential district the practicability of five buildings using one elevated fire tank is analyzed.
结合某小区五栋高层消防工程建设管理实践,分析了五栋高层共用一个高位消防水箱的可能性,对工程进行了设计变更,并对变更后的方案进行了经济分析,大大节省了工程投资,保证了五栋楼消防系统的合理性和完整性,同时体现了技术与经济相结合在工程建设管理中的重要性。
3.
This paper introduces two working principles for increasing pressure to solve the insufficient pressure in the fire tank.
介绍了解决消防水箱压力不足常用的2种增压设施的工作原理;通过实例计算,说明了2种增压设施的计算内容与计算方法,对2种增压方式的优缺点进行了比较;提出了设计中选用增压方式的原则。
5)  fire fighting pump
消防水泵
1.
In view of the issues encountered in construction and acceptance of the automatic fire system in this paper discussion is carried out in terms of the setting of fire fighting pump, correct installation of spray and pipe.
针对自动喷水灭火系统的安装过程 ,结合近年来在施工及工程验收中所遇到的问题 ,从消防水泵的设置 ,喷头与管道的正确安装等方面作了总结 ,并指出设计和施工部门应严格把关 ,才能使整个系统有效地发挥作
2.
Based upon design generalization of fire water systems of Jiangsu Shahe Shahe pumped storage plant and Mollasandra hydroelectric station in Iran discussion is made from pump house design, selection of fire fighting pump and other aspects.
对江苏沙河抽水蓄能电站及伊朗MOLLASADRA水电站消防给水系统的设计进行了总结,从取水泵站、消防水泵选择等作了阐述,提出水电站消防系统设计应因地制宜、巧妙地利用地形地貌,进行系统设计,以达到经济高效的效果。
6)  fire water tank
消防水箱
1.
Aecording to the relevant technical criterion on fire control,combinging with the practice in the building project inspection of fire control,we pointed out the commom mistakes in the design of fire water tank,and put forward the corresponding countermeasures.
根据现行消防技术规范的有关规定,结合建筑工程消防监督审核的工作实践,指出了消防水箱设计中常出现的错误并提出了相应的改正措施。
2.
In order to make the current design specification more practical for fire prevention, the personal views were presented about the problems existing in the installation of fire water tank and air pressure device, fire hazard rating established for auto-sprinkling system in residence, and fire resistance limit of fire curtain.
为了使现行防火设计规范更切合实际,分别就消防水箱及气压设备的设置、住宅设置自喷系统的火灾危险等级、防火卷帘的耐火极限等条文中出现的问题提出了个人看法,建议对规范中部分条文作适当调整。
补充资料:消防水系统


消防水系统
fire extinguishing water system

x laofongshu{x}tong消防水系统(fire extinguishing water sys-tem)包括火电厂消防用水的供给、储存、升压及常压维持、输送、自动喷水灭火系统及室内外消火栓设置等在内的整个系统。与消防水系统配套的有火灾的探测、报警及相应控制系统和移动式灭火设备及车辆等。 消防水系统设计的主要原则为:消防水系统一般应采用独立的管网;电厂在同一时间内一般只考虑发生一次火灾,只有当电厂面积超过10Oha时才考虑同一时间内发生两次火灾;重要的防火要求较高的建筑物及设备需考虑设有两种消防手段;消防蓄水池需满足3h的最大消防水量;至少设置两台消防水泵,其中一台备用,在可能时其中一台考虑由内燃机驱动;厂区消防管网按区域组成环形。 在电厂室外消防管网上设置室外消火栓和在主厂房及精煤系统建筑物内设置室内消火栓是最简单有效的灭火手段。此外,在重要的和防火要求较高的部位还需设置自动喷水灭火系统。电厂最常用的自动喷水灭火系统有:预作用喷水灭火系统、喷雾灭火系统和水幕系统。 预作用喷水灭火系统由火灾探测系统、闭式喷头、雨淋阀和充以低压空气的管道组成.该系统的管道内平时无水,以防止管道破漏及喷头损坏时的水演危害。发生火警时,通过火灾探侧系统控制雨淋阀向管道供水。喷头是否喷水还要根据各喷头处温度是否达到动作温度而定。预作用自动喷水灭火系统主要用于汽机轴承、运转层下及翰煤系统等处。 喷雾灭火系统由火灾探测系统、喷雾喷头、雨淋阀和管道等组成。发生火灾时,也通过火灾探测系统控制雨淋阀向管道内供水,管道充水后所有喷头即同时喷水。喷雾灭火系统主要用于多油设备.如变压器及汽机润滑油箱等。 水幕系统由水幕喷头、管道和控制阀等组成的阻火、隔火喷水系统。主要用于翰煤转运站的隔火,防止火势蔓延。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条