1) fire damper
防火阀
1.
Questions in terms of fire damper installation in current codes;
建筑规范中有关空调系统防火阀设置若干条文的商榷
2.
Selection of fire dampers in high-rise buildings;
高层民用建筑防火阀的选定
3.
Temperature-dependent fuse is one of the important parts in (smoke) fire dampers, and the fusible alloy is the key element of the fuse.
温度熔断器是(排烟 )防火阀中的重要部件之一 ,而其中的易熔片又是熔断器的关键元件。
2) fire valve
防火阀
1.
This paper introduces the selection of the fire valve for the ventilation system of underground garage, pressure air supply and passage gas exhausting system and the air conditioning system, and points out the important position of the fire valve in the fire-extinguishing works of the high-rising building.
介绍了地下车库通风系统、加压送风及走廊排烟系统、空调系统防火阀的选定,指出防火阀在高层建筑消防工程中的重要地位。
2.
This paper introduces the selection of the fire valves for the ventilation system of the underground garage,the ventilation system of the rooms in need of the gaseous fire units,the air-supply system and smoke-exhaust system and the air-conditioning system.
介绍了地下车库通风系统、需设气体灭火装置房间的通风系统、加压送风及走廊排烟系统、空调系统防火阀的选择。
3.
The paper discusses some common problems in the engineering design of the classification of air-conditioner system and smoke ventilation system as well as the set up of the fire valve.
本文对暖通设计中通风空调及排烟系统的划分、防火阀的设置等工程设计中常见的问题进行了探讨。
3) anti-backfire valve
防回火阀
4) fire gate
防火闸阀
5) fire protection pilot valve
防火滑阀
6) fire-resisting damper
防火阀,防火档板
补充资料:溢流阀、顺序阀、减压阀的比较
溢流阀 | 减压阀 | 顺序阀 | ||
控制油路的特点 | 通过调整弹簧的压力控制进油路的压力,保证进口压力恒定,p2=0 | 通过调整弹簧的压力控制出油口的压力,保证出口压力p2稳定 | 直控式-通过调定调压弹簧的压力控制进油路压力;夜控式-由单独油路控制压力 | |
出油口情况 | 出油口与油箱相连 | 出油口与减压回路相连 | 出油口与工作回路相连 | |
泄漏形式 | 内泄式 | 外泄式 | 内泄式 | |
进油口状态及压力值 | 常态 | 常闭(原始状态) | 常开(原始状态) | 常闭(原始状态) |
工作状态 | 进出油口相通,进油口压力为调整压力 | 进油口压力低于出油口压力,出油口压力稳定在调定值上 | 进出油口相通,进油口压力允许继续升高 | |
联接方式 | 并联 | 串联 | 实现顺序动作式串联作卸荷阀用时并联 | |
功用 | 定压、溢流或安全作用限压、稳压、保压 | 减压、稳压 | 不控制系统的压力,只利用系统的压力变化控制油路的通断 | |
进油腔压力p1控制阀芯移动 | 出油腔压力p2控制阀芯移动 | 进油腔压力p1控制阀芯移动 |