1) inverted asymmetric square-wave alternating current
逆变不对称交流方波
2) asymmetric square-wave
不对称交流方波
1.
The current-leakage protection technology of trolley network system based on asymmetric square-wave method;
基于不对称交流方波的直流架线漏电保护技术
3) non-symmetrical inverse
不对称逆变
1.
This essay intends to reveal the physical effect of the secondary-coil voltage response of transformer to the non-symmetrical inverse (SCVRTNSI).
以不对称方波电压作为物理模型 ,对不对称逆变的变压器次级响应进行了探讨 ,并得出如下结论 :在变压器初级输入周期性不对称方波电压的情况下 ,变压器次级输出方波电压的高电平电压与周期内低电平时间成正比 ,低电平电压与周期内高电平时间成正比 。
4) non-symmetrical square wave
不对称方波
6) dissymmetrical square wave with alternate frequency
变频不对称脉冲方波
1.
This paper focused on the usage of dissymmetrical square wave with alternate frequency for electro-generated FeO42-.
在CS-CMC双极膜电槽中,以多孔圆筒铸铁为阳极,结合变频不对称脉冲方波技术电解制备水处理剂高铁酸盐。
补充资料:换流站逆变侧交流系统故障
换流站逆变侧交流系统故障
AC system faults on inverter side of converer station
huanl一uZhonn{b一oneeJ一00!旧xltong guZhong换流站逆变侧交流系统故阵(AC systemfaults on inverter side of eonverter station)直流抽电受端交流系统发生的故障,包括三相短路、两相短路、两相对地短路、单相对地短路以及断线等.在常规的直流物电系统中,逆变器必须在受端交流系统提供的换相电压支持下才能正常工作。交流电网的故障会使逆变站交流母线电压的幅值、相位和波形发生变化,这些变化将可能引起逆变侧控制系统失去同步基准信号、阀触发系统储能不足,或逆变器的换相失败(见换流莽故降).逆变侧交流系统故障对直流系统的形响比整流侧的严重,其形响的程度往往以是否引发逆变器的换相失败或换相失败后是否能自行恢复正常来衡t。 三相对称故瘫,将由于故障地点的远近不同而使换相母线电压的下降程度不同,通常下降至额定电压的70%~60%时,逆变器就可能发生换相失败。由换相电流关系式可推导出三相交流电压下降造成逆变器发生换相失败的极限下降系数,即护万v[eos下。一eos(7。一y。。+600)〕式中。岛为换相电抗;几为直流运行电流,y。为关断角整定值;ym.二为极限关断角;U为故障前交流母线线电压有效值。如果采用低压限流(VDCL)的措施.通常在额定电压的40%时,还可维持直流系统运行。 交流系统不对称故障会使逆变站交流母线各相电压幅值和相位发生不同程度的变化。不对称故障除了降低换相电压外,还引起换相电压过零点的不对称移动,从而又直接影响到换流阀的关断角。通常不对称故障对关断角的影响比对称故障更严重。当逆变侧交流系统发生不对称故障时,逆变器往往会由于关断角变小而发生换相失败。