1) short-circuit current
短路电流
1.
Analysis on short-circuit current of 10 kV distribution network with neutral point ungrounded;
10kV配电网中性点不接地短路电流的分析
2.
Study of resolving scheme for short-circuit current exceeding limit of the 220 kV busbars of Feixi substation;
肥西变电站220kV母线短路电流越限解决方案的研究
3.
Short-circuit current level and it s limited measures for hubei power grid in 2007;
湖北电网2007年短路电流水平及限制措施
2) short circuit current
短路电流
1.
Connection solutions of limited short circuit current in power stations and substations;
限制电站和变电所中的短路电流的接线方案
2.
Analysis of effect of 1000kV UHV grid on the short circuit current of the Central China Grid and research on limiting measures of short circuit current;
特高压网架对华中电网短路电流水平的影响分析及限流措施
3.
Improving power supply capacity of Shanghai 220 kV district gird by controlling short circuit current;
控制短路电流提高220 kV分区电网可供电容量
3) short current
短路电流
1.
A new practical calculating method is proposed according to short current calculation in practical work.
根据实际工作中对短路电流的计算,提出一种新的实用计算法。
2.
A formula for short current calculation in low voltage power grid distribution was put forward.
提供了一般低压配电网主电源侧短路电流计算的公式。
3.
This paper presents that the selection of ratio and steady state test depend on the maximal short current,protection setting value and secondary load in .
通过举例,提出了保护用电流互感器的变比选择及稳态性能校验要根据系统的最大短路电流、保护定值、二次回路的二次负载综合考虑的方法,避免稳态特性不满足要求、电流传变特性变差,造成保护拒动、电流互感器损坏的情况发生。
4) short circuit
短路电流
1.
The breaking of 1000/500kV electromagnetic loop network and the influence of short circuit of UHV is also primary analyzed,based on them the measure and advice is presented.
对1000/500kV电磁环网解环、特高压电网对短路电流的影响等进行了初步分析,在此基础上提出了有关措施和建议。
2.
To obtain the batteries’ short circuit properties, the inner resistance and inductance must be known.
该参数作为直流电力系统短路电流计算是可行的。
3.
However, if is an out short circuit happens, the decrease of the short circuit of the Shunt Self generator will be slower than Shunt Self generator at the beginning, and during the second half time the decrease will become very fast which, the author suggests, may impair the excitation ability of the generator.
分析了 6 0 0MW机组全静态自并励励磁系统在发生机端三相短路时的暂态过程 ,得出自并励发电机短路电流在短路初始衰减比他励发电机慢 ,而后期又快 ,故而影响暂态过程中发电机的强励能力的结论 ,提出了应对的措施。
5) fault current
短路电流
1.
A novel topology of the solid state fault current limiter (SSFCL) is presented for medium- and high-voltage electric network.
新型限流器的固态器件和直流电抗参数不受电网允许的短路电流水平约束,所以可进行灵活优化设计。
2.
Due to the great difference be-tween normal operation and black-start,the fault current should be calculated again in the process of designing pro-tection scheme for system black-start.
在设计黑启动过程保护方案时,应针对不同的黑启动方案计算该种方式下的短路电流,制订合理的继电保护方案。
3.
Large number of loop operation, especially the electromagnetic loop operation, has made the fault current excess the switch capacity.
由于大量的环网运行方式,尤其是电磁环网运行方式,造成电网短路电流超出开关设备容量。
6) short circuit control
短路电流法
补充资料:短路电流
短路电流 short-circuit current 电力系统在运行中 ,相与相之间或相与地(或中性线)之间发生非正常连接(即短路)时流过的电流。其值可远远大于额定电流 ,并 取决于短 路点距电源的电气距离。例如,在发电机端发生短路时,流过发电机的短路电流最大瞬时值可达额定电流的10~15倍。大容量电力系统中,短路电流可达数万安。这会对电力系统的正常运行造成严重影响和后果。 三相系统中发生的短路有 4 种基本类型:三相短路,两相短路,单相对地短路和两相对地短路。其中,除三相短路时,三相回路依旧对称,因而又称对称短路外,其余三类均属不对称短路。在中性点接地的电力网络中,以一相对地的短路故障最多,约占全部故障的90%。在中性点非直接接地的电力网络中,短路故障主要是各种相间短路。 发生短路时,电力系统从正常的稳定状态过渡到短路的稳定状态,一般需3~5秒。在这一暂态过程中,短路电流的变化很复杂。它有多种分量,其计算需采用电子计算机。在短路后约半个周波(0.01秒)时将出现短路电流的最大瞬时值,称为冲击电流。它会产生很大的电动力,其大小可用来校验电工设备在发生短路时机械应力的动稳定性。短路电流的分析、计算是电力系统分析的重要内容之一。它为电力系统的规划设计和运行中选择电工设备、整定继电保护、分析事故提供了有效手段。 |
说明:补充资料仅用于学习参考,请勿用于其它任何用途。