1) hydraulic regulation
水力调度
1.
The characteristics of independent hydropower plants were introduced,the demand,content and method of hydraulic regulation for independent hydropower plants were discussed.
介绍独立运行水电站的特性,研究探讨引水式独立运行水电站水力调度的要求、内容和方法。
2) Hydraulic imbalance degree
水力失调度
3) relative hydraulic misadjustment
相对水力失调度
4) hydraulic stepout
水力失调
1.
Comprehensive and optimizational regularization of hydraulic stepout in the boiler system;
供热系统水力失调的综合优化治理
2.
The solving method of hydraulic stepout in water system of air conditioning;
谈空调水系统水力失调的解决办法
3.
In this article according to hydraulic stepout and difficult balancing regulation phenomena in outdoor heat supply network a economic and practical regulation method is introduced for hydraulic balancing based upon formula derivation, which realize the proper distribution of discharges between customers and provide guaranteed foundations for heating quality and energy saving.
针对室外供热管网水力失调严重 ,平衡调整困难的现象 ,通过公式推导 ,介绍了一套经济实用的水力平衡调整方法 ,从而使各热用户之间流量能够合理分配 ,为供暖质量的保证和节能提供了必备的基本条
5) hydraulic disorder
水力失调
1.
Analysis on hydraulic disorder of indoor two-pipe reverse-return heating systems with household metering;
分户计量户内双管同程式供暖系统水力失调问题分析
2.
Analyses on the hydraulic disorder problems in central heating system for single-storey houses(particularily for reverse return system),and puts forward the direction and measures to solve these problems.
对平房小区集中供热系统 (尤其是同程系统 )中存在的水力失调问题进行简要理论分析 ,提出解决失调问题的途径和措施 ,并附有应用实例 ,最后陈述平房集中供热系统的注意事项。
3.
Analyses the causes of hydraulic disorder in heating network and the technology of using hydraulic balance equipment to resolve hydraulic disorder problem,discusses the energy saving of multistage pump systems,and gives recommendations for using multistage pump systems.
分析了热网出现水力失调的原因及利用水力平衡设备解决系统水力失调问题的技术实质,探讨了多级泵系统的节能问题,对多级泵系统的应用提出了建议。
6) hydraulic maladjustment
水力失调
1.
In order to discuss the influence on the two-way electric valve for the hydraulic maladjustment caused by the change of hydraulic regime of air conditioning system,the author analyses the force of valve and discusses the valve actuator and its output force,then makes qualitative analysis and quantative analysis on fan-coil water system utilizing pressure diagram display.
为了研究空调水系统水力工况变化而产生的水力失调对电动两通阀动作的影响。
2.
The problems include hydraulic maladjustment, system air accumulation, system loss of water and pressure instability, etc.
通过近 2 0年的技改和运行管理经验 ,就我国目前供暖系统普遍存在的共性问题 ,如水力失调、系统积气、系统失水以及系统压力不稳定等问题做了简要分析 ,提出了解决方案 ,并列举了供暖系统技改的实
3.
The article explains the reason and result of hydraulic maladjustment in the heating network at No.
分析大连开发区 2 0号小区集中供热管网水力失调的成因及后果 ,提出了消除热网水力失调的解决方
补充资料:《水力发电》
综合性的水力发电技术月刊,国内外发行。于1954年创刊,编辑部设在北京。1958年10月至1980年 6月停刊,1980年7月复刊,至1988年底共出版176期。办刊方针是:宣传有关中国水电建设的方针政策,总结交流技术经验,推广先进的科技成果,探讨水电科学技术发展的方向和理论,以及水电在中国能源构成中的地位,促进水电建设的发展和科学技术水平的提高。刊物设有重大问题讨论、规划和动能经济、勘测设计施工、机电与金属结构、运行管理、试验研究、技术讲座、工程介绍、小水电、改革动态、信息服务、国外水力发电、国际水电新闻等十多个专栏。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条