Based on the environmental background of the developing reform of teaching and research in universities,according to the existed problems in the equipment purchase and management,combining the working practice,this article made a useful and beneficial exploration on university s equipment purchase and management.
基于高校教学和科研改革不断深入的环境背景,针对普遍存在于全国各高校在设备采购管理上的问题,结合工作实践,为搞好高校采购管理进行了有益的探索。
补充资料:气体绝缘金属封闭开关设备施工
气体绝缘金属封闭开关设备施工
installation of GIS
q{t一Jueyuonl一nshu fengb!k01guon shebe一sh}gong气体绝缘金属封闭开关设备施工(installa-tion of GIS)35kV及以下的GIS装里是柜式整体供货的,110kV及以上的设备是分若干隔室供货的.安装工作的要求是装里的绝缘合格,导电部分接触良好,SF。气体无泄漏,传动操作正确可靠. 安装前准备工作安装现场要做好防尘、防雨措施,保证照明和通风装里完好。检查及清理导体接触面和金属外壳,法兰接触面及0形密封圈应光滑无毛刺,用有机溶剂清洗干净。在法兰接触面上均匀涂上密封硅脂,然后把隔室连接,组装成开关装里的整体。要控制密封硅脂在空气中的暴礴时间,以防硅脂干结,降低密封效果。对SF。气体含水量进行检验,如不合格应进行处理.检查基础标高和中心线,以保证设备就位的位t正确。 本体安装将组装好的开关装里吊装就位,先将第一个间隔就位,找正找平固定好。再将相邻间隔就位、母线隔室就位、连接法兰面。再依次将各间隔就位连接、固定.要求各间隔连接处不受机械应力,以防止气体泄漏。就位固定后测试导电部件接触电阻.然后充SF。气体。充气前先按照制造厂规定的真空值和气体压力值,抽真空、充氮,要反复数次,以保证各隔室中无残留的空气和水分。然后注人经检验合格的SF‘气体.充气后检查各连接处无气体泄漏。最后进行操作机构安装、管道连接和外部电缆接线。 电气试验主要项目有:①测试开关、闸刀等部件的各特性参数;②连锁试验;③绝缘电阻测量、交流耐压试验;④验收合格后进行冲击合闸试验。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。