2) Pulse amperometric detection
脉冲安培检测
1.
Based on capillary electrophorersis with pulse amperometric detection technique, Konwledge of dissociation constants is important for prediction and understanding the migration behavior of analytes in capillary eletrophoresis.
基于毛细管电泳三脉冲安培检测技术,利用毛细管电泳中不同pH值条件下有效淌度(μeff)与缓冲溶液中[H+]的非线性关系,以及1/μeff缓冲溶液中[H+]的线性关系,测定了2,4-二氯苯酚(DCP)的离解常数。
3) Pulsed amperometric detection
脉冲安培检测
1.
Determination of carbohydrates in soy sauce by ion chromatography and pulsed amperometric detection
离子色谱-脉冲安培检测法测定酱油中的糖
2.
A chromatographic method was developed for the determination of inositol, galactitol, glycerol, xylitol, propylene glycol, sorbitol, mannitol, glucose, fructose, sucrose, mannose and galactose in tobacco feed liquid samples using high-performance anion-exchange chromatography coupled with pulsed amperometric detection.
建立了高效阴离子交换色谱分离-脉冲安培检测法测定烟草料液中的糖、糖醇以及醇类化合物的方法。
3.
CarboPac PA1 analytical column(2mm×250mm) and CarboPac PA1 guard column(2mm×50mm), and 5mmol/L NaOH+1mmol/L CH3COONa, stepwise elution with pulsed amperometric detection has been described.
以CarboPacPA1色谱柱,5mmol/LNaOH+1mmol/LCH3COONa等梯度淋洗,脉冲安培检测,该方法具有良好的重现性、线性关系(r2>0。
4) Pulsed amperometric detector
脉冲安培检测器
1.
With a pulsed amperometric detector,the detection limits were 0.
以45mm o l/L的N aOH溶液作淋洗液,采用强亲水性的IonPac A S16阴离子交换分析柱和脉冲安培检测器,在15m in内分离检测了B r-,S2O32-,I-和SCN-4种易极化阴离子,检测限(以3倍信噪比计)分别为0。
6) Integrated pulsed amperometric detection
积分脉冲安培检测
1.
A direct, sensitive, simple and practical method for the determination of amino acids and glucose in amino acid injection by anion exchange chromatography with integrated pulsed amperometric detection was developed.
用阴离子交换色谱 积分脉冲安培检测法测定了氨基酸注射液中 1 7种氨基酸和葡萄糖。
2.
Amino acids in yellow rice wine made in different places (Jiangxi, Shaoxing and Fujian) were measured by high-performance anion-exchange chromatography associated with integrated pulsed amperometric detection.
用阴离子交换色谱法-积分脉冲安培检测法测定了江西、绍兴、福建3地黄酒中的氨基酸。
补充资料:安培滴定法
安培滴定法 Amperometric titration 利用电解池中电流的变化指示滴定终点的电滴定分析方法。分为一个极化电极的安培滴定法和两个极化电极的安培滴定法。用滴汞电极为极化电极的一个极化电极的安培滴定法称为极谱滴定法。两个极化电极的安培滴定法称为死停终点法或双安培滴定法。 极谱滴定法是基于极谱法的原理在一定外加电压下滴加标准溶液,藉观察滴定过程中扩散电流的改变以确定滴定终点的容量滴定法。极谱滴定法装置就是一台简易极谱仪加一支滴定管(图1)。溶液中被测离子于一定的外加电压下在滴汞电极上还原(或氧化),此时由于浓差极化产生扩散电流。随着被测离子与滴定剂反应浓度越来越低,在滴汞电极上还原(或氧化)而产生的扩散电流越来越小,达到滴定终点时,扩散电流降至零。若将滴定剂体积与每加一次滴定剂后相应的电流读数作图,可得一直线。过滴定终点之后再将滴定剂体积与加滴定剂后的相应电流作图,又得一直线。将所得两条直线延长相交,交点所对应的滴定剂体积即为滴定终点。此法的优点是:①适用范围广,可用于沉淀反应、络合反应和氧化还原反应;②适用浓度范围宽,测量范围为0.1~10-4摩尔/升(mol/L)。缺点是:①选择性差,易受其他物质干扰;②操作麻烦。
双安培滴定法的装置和图1相似,两个电极都是铂电极,串联一个电流计指示电流。外加电压一般为几十毫伏。当滴定至电流发生突变时,表示滴定终点到达。滴定曲线的形状取决于滴定体系的可逆性程度( 图2)。双安培滴定法可用于沉淀反应、络合反应和氧化还原反应。在双安培滴定法中,应用较广的是碘滴定法,此外,在铈量法测定As3+和Sb3+离子,银量法测定卤素离子和CN-离子也常用此法指示终点 , 此外,也常用来指示库仑滴定法的终点。双安培滴定法的特点是装置简单,准确快速。
|