说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 阻抗保护
1)  impedance protection
阻抗保护
1.
Analysis on defects of impedance protection for transformer;
变压器阻抗保护缺陷的分析
2.
On basis of actual condition at site and with reference of theoretical analysis and calculation, analyzes the parameter setting for impedance at load side in quadrangular impedance protection at present time, points out its imperfection, brings up the setting method for impedance at the load side and therefore improves the accuracy for quadrangular impedance protection setting.
本文根据现场实际情况,结合理论分析计算,对目前四边形阻抗保护中负荷边阻抗值的参数取值进行了分析,指出了不足之处,提出了负荷边阻抗值新的整定方法,由此提高了四边形阻抗保护整定值的准确性。
3.
This article quantitatively analyzes the formation of remote impedance protection dead zone of WXB-63 computer feeder protection device, proposes the counter measures for elimination of remote protection dead zone by means of adjusting the offset resistance which may protect the whole length of line without modifying the soft and hard ware of device.
本文用短路试验数据定量地分析了WXB-63型微机馈线保护装置阻抗保护远端死区的形成,并提出了通过调整偏移电阻的方法来消除远端保护死区的解决方案,可以在不改变装置原有软、硬件的情况下保护线路全长。
2)  medium impedance busbar differential protection
中阻抗母差保护
1.
Analysis and countermeausres of one mal-operation of medium impedance busbar differential protection occurred in 110kV system;
一起110kV中阻抗母差保护误动的原因分析与措施
3)  high impedance differential protection
高阻抗差动保护
1.
Principle, setting and application of high impedance differential protection in large motor;
大型电动机高阻抗差动保护原理、整定及应用
4)  backup impedance protection
后备阻抗保护
1.
It is misunderstood that the backup impedance protection is high-ly sensitive to the inter-phase fault,inter-turn fault and single phase-to-ground fault at star winding of the windings of generator and transformer.
有些人误认为,后备阻抗保护对发电机定子绕组和变压器各侧绕组的相间、匝间短路、YN侧的单相接地短路有很高的灵敏度。
5)  low impedance busbar protection
低阻抗母线保护
6)  generator impedance protection
发电机阻抗保护
补充资料:星接阻抗和三角接阻抗的变换


星接阻抗和三角接阻抗的变换
transformation between starc-onnected and delta-connected impedances

x ing]一e乙日kongl介e sonJ一00}Iez日伙ongde匕一。一〕huon星接阻抗和三角接阻抗的变换(t ransfor-mation betweenstar一eonneeted and delta-eonneeted imPedanees)接成星形的三个阻抗和接成三角形的三个阻抗互相替代的等效变换。它们之间的关系可用一组变换公式表示。按这组公式,用星接阻抗替换三角接阻抗或者反过来,不会影响稳态下电路其他部分的正弦电压和电流,常用于对称三相电路的分析和计算。 图1为三个阻抗21、Z:、23接成星形(又称丫形)。图2为三个阻抗Z小22。、Zal接成三角形(又称△形)。它们之间的变换公式如下:人23土图1星接阻抗图2三角接阻抗(1)将星形连接变换成三角形连接212一Z:+22+2 122及3一22+za十警(1)、|冬|矛231一23+21+2321(2)将三角形连接变换成星形连接z、-二一典乒兴-) 艺‘2士乙“3十乙31…_2 oqZI,}Z。一下万~一二-二二-汁 乙‘2士乙23十乙3‘1_Z。IZoq}艺q一二二一~二,二二--,-二二-~J 乙12十乙23十艺32夕(2) 当三个星接阻抗相等,即21一Z:一23一z丫、三个三角接阻抗相等即212一223一231一Z△时,变换公式是 Z二一32丫,Z丫一Z△/3