说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 新风量
1)  fresh air volume
新风量
1.
Determination and control of fresh air volume in railway passenger vehicle;
铁路客车空调新风量的确定及控制
2.
On estimation of fresh air volume in air-conditioning system of large and medium emporiums and energy saving analysis;
大中型商场空调新风量取值与节能问题的分析
3.
On the estimation of customers runoff and fresh air volume in air-conditioning system of marketplace;
商场空调设计中客流量和新风量取值的探讨
2)  fresh air rate
新风量
1.
Presents the zoning of inner and peripheral zone,the determination of fresh air rate,and the design of water systems,smoke control and extraction systems,automatic control systems and adopted energy saving measures especially introducing outdoor air to inner zones to reduce temperature and delivering warm air from upper parts down to air conditioned area in the atrium.
介绍了空调系统内外区的划分,新风量的确定,以及空调水系统、防排烟系统和自控系统的设计和设计采用的节能措施,特别是冬季空调内区采用引入室外新风降温和将中庭上部的热风送至下部的节能措施。
2.
Taking an office building example, presents in detail the system arrangement, determination of fresh air rate, air distribution and control method of VAV systems.
介绍了变风量系统的计算基础、节能效果 ,以一办公楼为例 ,详细介绍了变风量系统的系统设置、新风量确定、气流组织、控制方
3)  Fresh air
新风量
1.
Study on fresh air of passenger carriage in underground railway;
地铁车厢内人员新风量的研究
2.
In order to reduce the cost of computer-room air conditioning system in a whole year and to consider energy saving,this paper studied the flow of fresh air and a whole year s operation and regulation of this system.
从节省机房空调系统全年运行费用、节约能源的角度出发,对新风量的控制及空调系统的全年运行调节进行了研究;提出了根据多工况的不同条件选择低能耗的空气处理方案,以及采用“新风焓值低于室内空气焓值时应尽量多取新风,否则尽量少取新风,并结合处理空气所需能耗”的新风量控制策略。
3.
Calculates and analyses the air conditioning loads in the inner zone, and studies the changes in minimum supply air rate and fresh air requirement of VAV air conditioning system in the inner zone, and provides the control values of minimum supply air rate.
计算分析了办公楼内区空调负荷,研究了内区变风量空调系统最小送风量和新风量的变化情况,给出了最小送风量的控制数值。
4)  air change flow
新风量
1.
The high concentration of carbon dioxide and deficiency of air change flow will affect the student study and depress effectiveness of lecturing course.
新风量不足,呼吸产生的二氧化碳可造成教室内CO_2浓度严重超标,影响学生学习,降低课堂教学效果。
2.
Indoor air change flow was determined by portable IR gas analyzer.
使用便携式红外线气体分析仪对室内新风量进行测定研究,仪器型号为GHX-3010E,示踪气体选取二氧化碳(CO_2)。
5)  fresh air requirement
新风量
1.
This paper introduced the importance of fresh air requirement in residential buildings and the sociological indexes related to the three pa-rameters in the ventilation equation, especially the relationship between fresh air requirement and real living state.
本文分析了住宅新风量的重要性,与通风方程中三个参数相关的社会学指标。
2.
Especially focused on problems encountered during practical designs of this type of air-conditioning system,such as how to set down the fresh air requirement,the special constitution of air-conditioning load,and varied air distributions and their cor.
分析信息化设备用房空调设计的特点,结合工程实例,总结了信息化设备用房空调设计与一般舒适性空调设计的不同点和应重视的问题;着重探讨了该类空调设计的特殊之处:新风量的确定、空调负荷构成的特点以及不同的气流组织形式与其相应的处理手段,并强调了各专业配合的重要性。
6)  New atmosphere quality
新风质量
补充资料:民用建筑最小新风量
摘要:《空调通风工程系统运行管理规范》(征求意见稿)
关键词:民用建筑 最小新风量

《空调通风工程系统运行管理规范》(征求意见稿):

空调通风系统运行期间,新风量宜满足下表的规定值,或者满足空气调节房间内二氧化碳浓度小于0.1%。

民用建筑主要房间人员所需新风量〔m3/(h·P)〕
房间类型
新风量
旅游旅馆
客房
3~5星级
≥30
2星级以下
≥22
餐厅、宴会厅、多功能厅
3~5星级
≥30
2星级以下
≥20
办公楼
≥30
住宅
≥30
中小学
教室
小学
≥11
初中
≥14
高中
≥17
文化娱乐场所
影剧院、音乐厅、录像厅
≥20
游艺厅、舞厅
≥30
酒吧、茶座、咖啡厅
≥10
图书馆、博物馆、美术馆
≥30
展览馆
≥20
体育馆
观众席
≥20
商场(店)、书店
设有空调装置
≥20
饭店(餐厅)
 
≥20
公共交通工具
旅客列车
车厢
≥20
轮船
客舱
≥20
飞机
客舱
≥25
公共交通等候室
侯车室、侯船室(二等以上)
≥20
侯机室
≥20
医院
侯诊室
≥30

《采暖通风与空气调节设计规范》(报批稿)第3.1.9条:

(强制性条文)建筑物室内人员所需最小新风量,应符合以下规定:

① 民用建筑人员所需最小新风量按现行有关卫生标准确定;

② 工业建筑应保证每人 少于30 m3/h的新风量。

表3.1.9 民用建筑主要房间人员所需的最小新风量参考值〔m3/(h·P)〕
房间类型
新风量
参考依据
旅游旅馆、饭店
客房
3~5星级
≥30
GB9663-1996
2星级以下
≥20
GB9663-1996
餐厅、宴会厅、多功能厅
3~5星级
≥30
GB9663-1996
2星级以下
≥20
GB9663-1996
会议室、办公室、接待室
3~5星级
≥50
GB9663-1996
2星级以下
≥30
GB9663-1996
医院
病房
≥35
GB9663-1996
≥50
GB9671-1996
诊室
≥25
GB9671-1996
手术室
≥60
GB9671-1996
办公楼
办公室(无烟)
高级
35~50
室内空气质量标准
一般
25~30
室内空气质量标准
会议室(无烟)
 
30~50
室内空气质量标准
学校
教室
小学
≥11
GB/T17226-1998
初中
≥14
GB/T17226-1998
高中
≥17
GB/T17226-1998
文体建筑
影剧院、音乐厅
观众厅
≥20
GB 9664-1996
体育馆
观众厅
≥20
GB 9668-1996
室内游泳池
 
10~15
GB 9668-1996
展览馆、博物馆
展厅、观众厅
10~15
GB 9669-1996
图书馆
阅览室
≥15
GB 9669-1996
商店
 
10~20
GB 9670-1996

注 :大学教室可参照会议室标准。

说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条