1) flooding
[英]['flʌdiŋ] [美]['flʌdɪŋ]
液泛
1.
In view of the flooding problem existing commonly in gas treatment plant,focused on the CNOOCC's aMDEA03 process and combined the running experiences of the other CO2 removal units,the reasons causing the flooding of MDEA solution regenerator were classified and discussed,and the optimized experiences and precautionary measures based on the advance control were summarized.
针对困扰净化装置的液泛问题,以中海化学aMDEA03脱碳工艺为考察重点,结合其它净化装置的运行经验,对再生塔液泛的原因进行了归类和分析,总结了基于事前控制的优化经验与预防措施。
2.
From the functional relationship between the flooding gas and liquid velocities derived from the two-film theory based on the Bernoulli equation,two parameters which are relative to the packing property were investigated.
根据从双膜理论出发由Bernou lli方程得到的液泛气速与液速之间的函数关系,考察了两个与填料有关的模型参数:一个是由填料比表面积a和床层空隙率ε所组成的填料因子a/3ε,另一个是本文定义的填料结构参数。
3.
The flooding rate and pressure drop of hydrogenwater liquid phase catalyst exchange bed with various packings are discussed in 50 mm×680 mm and 20 mm×290 mm glass columns.
在50mm×680mm和20mm×290mm玻璃柱中,用氢 氘水研究了催化交换床层不同填料的液泛及床层压力降的变化。
2) flooding point
液泛点
1.
Through analyzing the operating conditions and calculating the flooding point and spray density of the desulfurizatiion system, the overload of the desulfurization tower was determined to be the main cause of sulfur paste entraining.
通过对系统的运行工况进行分析,对塔的液泛点、喷淋密度进行计算,确定了PDS栲胶脱硫装置出现硫膏严重夹带现象的主要原因是脱硫塔负荷过高,采取两塔并联等措施后,系统恢复稳定运行。
3) flooding throughout
液泛通量
1.
The effects of the operation parameters such as pulsed amplitude,pulsed frequency,flow velocity and flow ratio,and the plate spacing on the hydrodynamics characteristics of flooding throughout,flooding-holdup and disperse phase holdup in normal operation were studied through a 100 mm discs and doughnuts pulsed extraction column in 1 mol/L HNO_3 solution-30%TRPO-kerosene solution system.
以体积分数30%三烷基氧膦(TRPO)煤油溶液和1 mol/L硝酸溶液为体系,在100 mm折流板脉冲萃取柱中考察了折流板脉冲萃取柱的操作参数(脉冲振幅、脉冲频率、流速和流比)和结构参数(板间距)对其水力学性能(液泛通量、液泛存留分数和正常操作时分散相存留分数)的影响。
2.
The effects of the pulsed amplitude,pulsed frequency,flow velocity and flow ratio and the plate spacing on the hydrodynamics characteristics,such as flooding throughout,flooding-holdup and holdup were studied for 30% TBP-kerosene/HNO3 solution in a 100 mm-diameter discs and doughnuts pulsed extraction column.
在100 mm折流板脉冲萃取柱中实验考察了30%TBP-煤油1 mol/L HNO3体系下的萃取柱操作参数(脉冲振幅、脉冲频率、流速和流比)、结构参数(板间距)对萃取柱水力学性能(液泛通量、液泛存留分数和正常操作时分散相存留分数)的影响。
4) flooding velocity
液泛速度
1.
The dispersed holdup and flooding velocity of an agitating extraction column with a diameter of 90 mm are investigated.
在内径为 90 mm的搅拌萃取塔中 ,对分散相滞存率和液泛速度进行了研究 。
5) pressure drop at flooding point
液泛压降
6) Flooding Method
液泛法
补充资料:液泛
在气液或液液两相逆流操作的传质设备中,当两相流速高达某一极限值时,一相将被另一相夹带而倒流,设备的正常操作遭到破坏的现象。设备内刚好发生液泛的两相流速称为泛点速度,但通常用连续相的流速来标志。泛点速度是设备通过能力的上限。在不同设备中,产生液泛的原因及其具体现象互不相同。
在气(汽)液接触的板式塔内,液泛可能是由于降液管通过能力的限制所致,也可能由于发生过量的雾沫夹带。在正常操作中,由于液体流经降液管和气体流经塔板所受到的流动阻力,降液管中液面高于塔板上的液面,当气液流量过大时,降液管内液体将升到上一层塔板,产生液体壅塞而发生液泛。当雾沫夹带量过大时,会使大量液体随气体而倒流,板上液体增厚,且流经降液管的液体量大大增加,最终也使降液管不能负担而发生液泛,无论是哪种原因造成液泛,都导致塔内积液。在操作中,若气体流量不变而塔板压降持续增加,预示液泛即将发生。
在气(汽)液逆流接触的填充塔中,若保持液体流量不变而使气体流量增到某个临界值(即泛点)时,塔内持液量(单位体积填料层内积存的液体量)会持续增加,气体压降也随之急剧上升,就会导致发生液泛。泛点气速随液体流量的增加而减小。液泛速度可从气体压降随气速变化的曲线确切判定。当气相流量不大,因液相流量过大而发生液泛时,液膜合并而转变成为连续相,气体则鼓泡通过填料层。相反,在气液比较大时发生的液泛,部分液体随气体一起从塔顶溢出。
在液液逆流接触的塔设备中提高两相流速时,分散相(液滴)的滞留率(分散相在填料空隙中所占的体积分率)随之增大。当流速达到某一临界值时,滞留率达到极大值,也就发生液泛。此时分散相大量出现于连续相出口,或发生连续相的转换。
液泛现象相当复杂,液泛速度与两相的流量比和密度差,设备结构和尺寸,以及两相的粘度、表面张力和起泡性等都有关。目前,仅有一些估算泛点速度的经验式。不恰当的设备结构设计(如填充塔中填料支承板开孔不足,板式塔中降液管太小等),会使设备在运行中容易发生液泛,降低设备的处理能力。
在气(汽)液接触的板式塔内,液泛可能是由于降液管通过能力的限制所致,也可能由于发生过量的雾沫夹带。在正常操作中,由于液体流经降液管和气体流经塔板所受到的流动阻力,降液管中液面高于塔板上的液面,当气液流量过大时,降液管内液体将升到上一层塔板,产生液体壅塞而发生液泛。当雾沫夹带量过大时,会使大量液体随气体而倒流,板上液体增厚,且流经降液管的液体量大大增加,最终也使降液管不能负担而发生液泛,无论是哪种原因造成液泛,都导致塔内积液。在操作中,若气体流量不变而塔板压降持续增加,预示液泛即将发生。
在气(汽)液逆流接触的填充塔中,若保持液体流量不变而使气体流量增到某个临界值(即泛点)时,塔内持液量(单位体积填料层内积存的液体量)会持续增加,气体压降也随之急剧上升,就会导致发生液泛。泛点气速随液体流量的增加而减小。液泛速度可从气体压降随气速变化的曲线确切判定。当气相流量不大,因液相流量过大而发生液泛时,液膜合并而转变成为连续相,气体则鼓泡通过填料层。相反,在气液比较大时发生的液泛,部分液体随气体一起从塔顶溢出。
在液液逆流接触的塔设备中提高两相流速时,分散相(液滴)的滞留率(分散相在填料空隙中所占的体积分率)随之增大。当流速达到某一临界值时,滞留率达到极大值,也就发生液泛。此时分散相大量出现于连续相出口,或发生连续相的转换。
液泛现象相当复杂,液泛速度与两相的流量比和密度差,设备结构和尺寸,以及两相的粘度、表面张力和起泡性等都有关。目前,仅有一些估算泛点速度的经验式。不恰当的设备结构设计(如填充塔中填料支承板开孔不足,板式塔中降液管太小等),会使设备在运行中容易发生液泛,降低设备的处理能力。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条