说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 运行维护
1)  operation and maintenance
运行维护
1.
Study on the operation and maintenance model;
贵州电力通信网运行维护方式探索
2.
Deviation analysis of high voltage current transformer and the attention of operation and maintenance;
高压电流互感器的误差分析及运行维护注意事项
3.
Study on operation and maintenance of 10 kV relay protection equipment;
10kV继电保护装置的运行维护研究
2)  operation maintenance
运行维护
1.
Discussion on DC system operation maintenance in transformer substation;
浅谈变电站直流系统运行维护的几个问题
2.
This paper introduces three main methods for measuring the industrial frequency grounding resistance in the operation maintenance, and based on the field measuring results, probes into the reliability and methods/procedures of the data measured by using the clamp-meter.
介绍了运行维护工作中测量工频接地电阻的3种主要方法,并以现场测量结果为依据,探讨了钳表法测量数据的可信度及方法步骤。
3.
The functions and composition of geographic information system for heating power as well as the practical experience for construction and operation maintenance of the system are summarized.
总结了热力地理信息系统的功能、组成及系统建设和运行维护的实践经验。
3)  running maintenance
运行维护
1.
The grounding for lighting protection and running maintenance resolving planning of residential quarters weak current system
住宅区弱电系统防雷接地及运行维护解决方案
2.
Through the practical application of the 220kV transformer\'s automatic bus transfer equipment, this paper studies the scheme principle and request of the 220kV transformer\'s automatic bus transfer equipment, expatiates several modus operation on compiling action logical,installation,debugging and running maintenance of transformer\'s automatic bus transfer equipment.
通过湖北荆州地区220 kV主变备自投的实际应用,研究了220 kV主变备自投配置的基本原则和要求,阐述了主变备自投装置在动作逻辑编写、安装调试和运行维护方面的一些实际做法,为220 kV站主变备自投装置的推广应用及安全可靠运行提供了工程经验,为备自投装置的安装、运行、维护等方面给出了指导意见。
4)  maintenance [英]['meɪntənəns]  [美]['mentənəns]
运行维护
1.
Study on maintenance of Railway Waybill System;
货运制票系统运行维护工作探讨
2.
The Transmission Line Maintenance in Ice and Snow Conditions;
冰雪灾害下输电线路的运行维护工作
3.
In this paper,in order to provide references for the maintenance of 1000kV UHV transmission lines,from practical domestic situation of 1000kV UHV transmission lines,combining with the operating conditions and experiences of high voltage(HV),extra high voltage(EHV) in China and UHV transmission lines abroad,the characteristics of lightning stroke,pollution flash.
我国正在积极发展结构参数高、运行可靠性要求高的1000kV特高压交流输电线路,为了给线路的运行维护提供参考,从我国实际情况出发,结合国内高压、超高压线路和国外特高压线路的运行情况,分析了特高压线路雷击、污闪、风偏、覆冰舞动等故障的特点,提出了相应的防治措施;明确了线路检测工作的重点,分析了在1000kV特高压交流输电线路运行维护中应用红外、紫外等检测技术和开展在线监测和状态检修的可行性和必要性;分析了线路巡视工作的要点,探讨了直升飞机巡视在1000kV特高压交流输电线路中的应用;研究了1000kV特高压交流输电线路的带电作业技术,确定了带电作业的安全距离和组合间隙,提出了人体安全防护方法,并讨论了加装保护间隙的作业方式。
5)  operating maintenance
运行维护
1.
Improvement and operating maintenance of miter gate bottom pivot;
京南电站人字闸门底枢改造及运行维护
2.
Proper selection and operating maintenance of the batteries in the subway power supply system
地铁供电系统用蓄电池的合理性选择及运行维护
3.
Over-voltage and insulation coordination, anti-pollution characteristic, lightning performance, electromagnetic environment, equipment research, operating maintenance etc.
过电压与绝缘配合、耐污特性、防雷特性、线路环境、设备研制、运行维护等是关系1000kV交流特高压输电线路设计、建设和可靠运行的关键技术。
6)  running attention
运行维护
1.
It expounds technical measures of the running attention of the circuit breaker.
阐述了真空断路器运行维护的技术措施。
2.
This paper describes the structure and application of a capacitive voltage transformer and presents running attention and electric power field test.
叙述了电容式电压互感器的结构和应用 ,介绍了其运行维护情况及电力现场试验。
补充资料:变压器运行维护


变压器运行维护
transformer operation and maintenance

b一Onyaq}yunxlng we{hu变压姗运行维护(transformer operation andmalntenance)电力变压器进行电压变换及能量传翰的工作状态以及在其工作状态或在不工作状态期间所进行的技术处理,以保持其正常的工作状态或消除已基礴出的缺陷。对变压器运行的要求是:安全可靠,高效经济;正常负荷下输出电压保持在规定的范围内;紧急悄况下能按规定的方式超铭牌出力运行。当单台变压器容t不够时,可以采用两台以上并联运行的方式.为实现对变压器运行的要求,有关标准规定了变压器的使用条件、允许温升、超铭牌出力、并列运行、运行监视和维护检修事项。 使用条件变压器的正常使用条件为:海拔不超过1。。。m;最高气温十40’C,最高日平均气温+30℃,最高年平均气温+20’C,最低气温对户外和户内分别为一30℃和一5℃;冷却水最高人口温度为+30℃;电压波形近似于正弦波,多相电源电压近似对称。特殊的使用条件下,变压器的额定参数要有相应的改变。例如,当冷却空气温度超过上述正常值,但超过值不大于10℃时,则温升限值按该超过值降低一个相同的值;运行在海拔高度超过l000m的场合,以每500m为一级,温升限值按下列数值减少:油浸自冷式变压器减少2.0%,油浸风冷式及强油风冷式变压器减少3.0%。此外,对十分恶劣的运行条件,例如严重污秽区、地展频发区等,变压器应该有相应的特殊技术条件。 允许温升变压器某一部位的温度高于冷却空气温度或冷却水人口温度的允许差值。变压器内部各部位的温升是不相同的.对油浸式变压器,油的温度自下而上逐渐升高,绕组的温度也有同样的变化规律,其温度分布可简化为如图所示:绕组温度和油的温度在垂直方向上按两条平行直线分布,两者之间有一恒定的温度差山;绕组在同一平面上温度也不相同,饼式线圈的绕组中部散热条件较差,因此最热点的温升还会高于该平面上的平均温升值。 离度顶娜璐妞一T~最翩平均倪组z,,坟一.一翻一泊一.目一均一阳,一平一日一开 绕组和油的温度分布图 变压器绝缘的寿命就是由最热点的温度所决定的。通常的温升试验只能测得变压器上层油温及冷却器各部位的油温,还可用测绕组直流电阻的方法来推算各绕组的平均温度。但最热点的温度是无法用常规的方法侧量的。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条